DNA Sequencing
- (1)
- (11)
- (2)
- (1)
- (23)
- (11)
- (13)
- (6)
- (19)
- (79)
- (2)
- (8)
- (11)
- (1)
- (53)
- (4)
- (1)
- (1)
- (1)
Filtered Search Results
Invitrogen™ Collibri™ Library Quantification Kit
Invitrogen™ Collibri™ Library Quantification Kit includes a ready-to-use master mix optimized for Illumina NGS library quantification and a library dilution buffer
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Platinum™ II Taq Hot Start DNA Polymerase |
| GC-Rich PCR Performance | Low |
| Content And Storage | Store at -20°C. |
| Format | Kit |
| Product Type | Library Quantification Kit |
| For Use With (Equipment) | 7500 Fast System, 7900HT Fast System, QuantStudio™, ViiA™ 7 System, StepOne™ System, StepOnePlus™ System |
| Sample Type | DNA,RNA |
| PCR Method | qPCR |
| For Use With (Application) | Illumina NGS Library Quantification |
| Test Time | Standard |
| Product Line | Collibri™ |
| Detection Method | SYBR |
Applied Biosystems™ BigDye™ Terminator v3.1 Cycle Sequencing Kit
The BigDye™ Terminator v3.1 Cycle Sequencing Kit's robust, highly flexible chemistry is ideal for de novo sequencing, resequencing, and finishing with PCR product, plasmid, fosmid, and BAC templates.
| Format | 12-well Strips,8-well Strip,96- or 384-well Plate |
|---|---|
| Product Type | Sequencing Buffer |
| For Use With (Equipment) | SeqStudio™ Genetic Analyzer, SeqStudio™ Flex Series Genetic Analyzer, 3500/3500xL Genetic Analyzer, 3730/3730xl DNA Analyzer Thermal Cyclers: GeneAmp™ PCR System 9700 Dual Series, Veriti™ Fast 96‐well and 384‐well Thermal Cyclers |
| Technique | Fluorescent Dye Terminator Sequencing |
| Product Line | BigDye™ Terminator |
Applied Biosystems™ BigDye™ Terminator v1.1 & v3.1 5X Sequencing Buffer
This sequencing buffer is optimized for use with BigDye™ Terminator v1.1 and v3.1 Cycle Sequencing Kits.
| Shipping Condition | Room Temperature |
|---|---|
| Buffer | Sequencing Buffer |
| Content And Storage | Store at 2°C to 8°C. |
| Form | Liquid |
| Concentration | 5X |
| For Use With (Application) | Standard Sequencing |
Applied Biosystems™ BigDye™ Terminator v1.1 Cycle Sequencing Kit
This BigDye™ Terminator v1.1 Cycle Sequencing Kit is designed for specialty applications that require optimal basecalling adjacent to the primer and for sequencing short PCR product templates with rapid electrophoresis run modules.
| Product Type | Sequencing Buffer |
|---|---|
| For Use With (Equipment) | SeqStudio™ Genetic Analyzer, SeqStudio™ Flex Series Genetic Analyzer, 3500/3500xL Genetic Analyzer, 3730/3730xl DNA Analyzer Thermal Cyclers: GeneAmp™ PCR System 9700 Dual Series, Veriti™ Fast 96‐Well and 384‐Well Thermal Cyclers |
| Technique | Fluorescent Dye Terminator Sequencing |
| Template Compatibility | BAC DNA, Plasmid DNA (≤15 Kb), PCR Amplicons, Single Stranded DNA |
| Product Line | BigDye™ Terminator |
Applied Biosystems™ POP-7™ Polymer For 3500 Dx Series
Conveniently offered in easy to use pouch packages
| Product Type | POP-7™ Polymer |
|---|---|
| For Use With (Equipment) | 3500 Dx Series |
| Size | 1 Kit |
Applied Biosystems™ 3730 Running Buffer (10X)
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
The concentrated Running Buffer is used for electrophoresis on Applied Biosystems™3730 and 3730XL DNA Analyzers.
Applied Biosystems™ Sequenase Version 2.0 DNA Polymerase
Sequenase™ Version 2.0 DNA Polymerase is a genetically engineered form of T7 DNA polymerase. Unlike the wild-type enzyme it has virtually no 3'→5' exonuclease activity.
| Polymerase | Genetically-Engineered form of T7 DNA Polymerase |
|---|---|
| Product Type | Sequenase Version 2.0 DNA Polymerase |
| Purity | 0.95 |
| Concentration | 13 units/μL |
| For Use With (Application) | Sequencing |
Applied Biosystems™ Sanger Sequencing Kit
Sanger Sequencing Kit includes all reagents needed for sample preparation for sanger sequencing
Invitrogen™ SequenceRx Enhancer Solution A
Designed to improve length and quality of sequencing data from difficult sequencing templates
Applied Biosystems™ BigDye™ Direct Cycle Sequencing Kit
The BigDye™ Direct Cycle Sequencing Kit, part of the BigDye™ product family, is a complete kit for your PCR and Sequencing needs.
| Shipping Condition | Dry Ice |
|---|---|
| Format | 8-well Strip,96-well Plate |
| Product Type | Direct Cycle Sequencing Kit |
| Technique | Fluorescent Dye Terminator Sequencing |
| For Use With (Application) | Comparative Sequencing (Germline Mutations - 30:70 Heterozygotes), Comparative Sequencing (Germline Mutations - 50:50), GC-Rich Sequencing (>65%), GT-Rich or Difficult Template Sequencing, Standard Sequencing, Gap Closure, Homopolymer A or T, AT-Rich Sequencing (>65%), Comparative Sequencing (Germline Mutations -10:90 Heterozygotes) |
| Template Compatibility | BAC DNA, Cosmids, Lambda DNA, PCR Amplicons (10:90 Heterozygotes), Plasmid DNA (≤15Kb), Genomic DNA (Bacterial), Fosmids, PCR Amplicons (50:50 Heterozygotes), PCR Amplicons (30:70 Heterozygotes) |
| Product Line | BigDye™ |
Thermo Scientific™ Jurkat Genomic DNA
Use this pure human genomic DNA as a control in DNA methylation analysis, genomic DNA library construction, PCR, and Southern blotting.
Applied Biosystems™ GeneScan™ 1200 LIZ™ dye Size Standard
The GeneScan™ 1200 LIZ™ Size Standard is a fifth dye (LIZ™) labeled high density size standard for the reproducible sizing of fragment analysis samples.
Applied Biosystems™ POP-7™ Polymer for 3730/3730xl DNA Analyzers
POP-7™ Polymer is a separation matrix for the 3730 and 3730xl DNA Analyzers. POP-7™ Polymer is customized for DNA sequencing and fragment analysis.
| Accuracy | 98.5% up to 900 bases (for 50 cm capillary), 98.5% up to 700 bases (for 36 cm capillary) |
|---|---|
| Product Type | Polymer |
| For Use With (Application) | Standard Sequencing, Fragment Analysis (Denaturing) |
| Test Time | 1 hr for 36 cm capillary (std. seq.), 2 hrs for 50 cm capillary (long read seq.) |
| Product Line | POP-7™ |
Applied Biosystems™ GeneScan™ 1000 ROX™ dye Size Standard
The GeneScan™ 1000 ROX™ Size Standard is an internal lane size standard developed for use with Applied Biosystems™ fluorescence-based DNA electrophoresis systems.