Filtered Search Results
Applied Biosystems™ DS-33 Matrix Standard Kit (Dye Set G5)
Software for these instruments uses the multicomponent matrix to automatically analyze the five different colored fluorescent dye-labeled samples.
Borane-tetrahydrofuran complex, 1M solution in THF, Stabilized, AcroSeal™
CAS: 14044-65-6 | C4H11BO | 85.94 g/mol
| Molecular Weight (g/mol) | 85.94 |
|---|---|
| InChI Key | RMCYTHFAWCWRFA-UHFFFAOYSA-N |
| Density | 0.8760g/mL |
| Treatment(s) | Stabilized |
| PubChem CID | 11062302 |
| Name Note | 1M solution in tetrahydrofuran, stabilized |
| Fieser | 01,199; 02,106; 03,76; 04,124; 05,184; 06,161; 07,89; 12,65; 17,101 |
| Formula Weight | 85.94 |
| Color | Colorless |
| Physical Form | Liquid |
| Chemical Name or Material | Borane-tetrahydrofuran complex |
| SMILES | B.C1CCOC1 |
| Merck Index | 15, 1336 |
| Concentration | 0.96 to 1.08M |
| CAS | 109-99-9 |
| Health Hazard 3 | GHS P Statement Keep away from heat/sparks/open flames/hot surfaces. - No smoking. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Handle under inert gas. Protect from moisture. Wear protective gloves/protective clothing/eye protection/face protection. IF SWALLOWED: rinse mouth. Do NOT induce vomiting. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician. |
| MDL Number | MFCD00012429 |
| Health Hazard 2 | GHS H Statement May cause respiratory irritation. Causes serious eye damage. In contact with water releases flammable gases which may ignite spontaneously. Causes skin irritation. Harmful if swallowed. Highly flammable liquid and vapour. Suspected of causing cancer. Reacts violently with water. May form explosive peroxides. May cause drowsiness or dizziness. |
| Flash Point | −22°C |
| Packaging | AcroSeal™ Glass bottle |
| Solubility Information | Solubility in water: reacts. |
| Health Hazard 1 | Danger |
| Synonym | borane-tetrahydrofuran complex,tetrahydrofuran borane,bh3.thf,borane tetrahydrofuran complex solution,borane-d3-thf complex solution,borane-tetrahydrofuran,unii-5ear4err1l,oxolane borane,boron; oxolane,borane thf |
| TSCA | TSCA |
| IUPAC Name | oxolane borane |
| Molecular Formula | C4H11BO |
| EINECS Number | 237-881-8 |
| Specific Gravity | 0.876 |
| Linear Formula | LiAlH4 |
|---|---|
| Molecular Weight (g/mol) | 37.95 |
| Color | Gray |
| Physical Form | Turbid Solution |
| Chemical Name or Material | Lithium Aluminum hydride |
| SMILES | [Li+].[AlH4-] |
| Merck Index | 15, 344 |
| InChI Key | OCZDCIYGECBNKL-UHFFFAOYSA-N |
| Density | 0.9000g/mL |
| PubChem CID | 21226445 |
| Percent Purity | 3.9 to 4.5% (as LiAlH4) |
| Fieser | 01,581; 02,242; 03,176; 04,291; 05,382; 06,325; 07,196; 08,286; 09,274; 10,236; 11,289; 12,272; 13,61; 14,190; 15,184; 16,133; 17,162 |
| CAS | 109-99-9 |
| Health Hazard 3 | GHS P Statement Keep away from heat/sparks/open flames/hot surfaces. - No smoking. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Handle under inert gas. Protect from moisture. Wear protective gloves/protective clothing/eye protection/face protection. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician. |
| MDL Number | MFCD00011075 |
| Health Hazard 2 | GHS H Statement May cause respiratory irritation. Causes skin irritation. Causes serious eye damage. Highly flammable liquid and vapor. In contact with water releases flammable gases which may ignite spontaneously. May form explosive peroxides. Suspected of causing cancer. Harmful if swallowed. May cause drowsiness or dizziness. |
| Flash Point | −17°C |
| Solubility Information | Solubility in water: vigorous reaction. |
| Health Hazard 1 | Danger |
| Synonym | lithium aluminum hydride,lithium aluminum hydride,aluminum lithium hydride,lithiumaluminiumhydride,aluminum iii lithium hydride,lithium alanate,lithium aluminum tetrahydride,lithiumaluminiumhydrid,litiumaluminum hydride,lithim aluminum hydride |
| IUPAC Name | lithium(1+) alumanuide |
| Molecular Formula | AlH4Li |
| Formula Weight | 37.95 |
| Specific Gravity | 0.9 |
Applied Biosystems™ DS-31 Matrix Standard Kit (Dye Set D)
Suitable for Dye Set D spectral calibration, on ABI PRISM™ Analyzers: 3100-Avant™, 3100, and 3730. Supports 4-Dye fragment analysis applications.
Applied Biosystems™ DS-30 Matrix Standard Kit (Dye Set D)
This Matrix Standard Set is used to generate the 'multicomponent matrix' required when analyzing fluorescent dye-labeled DNA fragments.
hydrogen chloride, 4N solution in 1,4-dioxane, AcroSeal™
CAS: 7647-01-0 | ClH | 36.46 g/mol
| Linear Formula | HCl |
|---|---|
| Molecular Weight (g/mol) | 36.46 |
| ChEBI | CHEBI:17883 |
| InChI Key | VEXZGXHMUGYJMC-UHFFFAOYSA-N |
| Density | 1.0500g/mL |
| PubChem CID | 313 |
| Name Note | 4N solution in 1, 4-dioxane |
| Formula Weight | 36.45 |
| Color | Colorless to White |
| Physical Form | Crystals or Crystalline Powder |
| Chemical Name or Material | Hydrochloric acid |
| SMILES | Cl |
| Merck Index | 14, 4794 |
| Concentration | 3.95 to 4.40N |
| CAS | 123-91-1 |
| Health Hazard 3 | GHS P Statement: Wear eye protection/face protection. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF SWALLOWED: rinse mouth. Do NOT induce vomiting. Immediately call a POISON CENTER or doctor/physician. Use personal protective equipment as required. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Avoid breathing dust/fume/gas/mist/vapors/spray. Keep container tightly closed. IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell. Wear protective gloves/protective clothing/eye protection/face protection. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Ground/Bond container and receiving equipment. WARNING: The information provided on this web site was developed in compliance with European Union (EU) regulations and is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling and use. It is not to be considered as either a warranty or quality specification. |
| MDL Number | MFCD00011324 MFCD00792839 |
| Health Hazard 2 | GHS H Statement: Causes severe skin burns and eye damage. Suspected of causing cancer. Toxic if inhaled. Highly flammable liquid and vapor. May form explosive peroxides. Repeated exposure may cause skin dryness or cracking. |
| Flash Point | 17°C |
| Packaging | AcroSeal™ Glass Bottle |
| Solubility Information | Solubility in water: soluble. Other solubilities: soluble in most organic solvents |
| Health Hazard 1 | Danger |
| Synonym | hydrochloric acid,hydrogen chloride,muriatic acid,chlorohydric acid,acide chlorhydrique,chlorwasserstoff,spirits of salt,hydrogen chloride hcl,anhydrous hydrochloric acid,chloorwaterstof |
| IUPAC Name | hydrogen chloride |
| Molecular Formula | ClH |
| Specific Gravity | 1.05 |
| Linear Formula | NH3 |
|---|---|
| Molecular Weight (g/mol) | 17.03 |
| ChEBI | CHEBI:16134 |
| Color | Colorless to Yellow |
| Physical Form | Liquid |
| Chemical Name or Material | Ammonia |
| SMILES | N |
| Merck Index | 15, 488 |
| Concentration | 6.0 to 7.5N |
| InChI Key | QGZKDVFQNNGYKY-UHFFFAOYSA-N |
| Density | 0.7700g/mL |
| PubChem CID | 222 |
| Name Note | 7N solution in methanol |
| CAS | 67-56-1 |
| Health Hazard 3 | GHS P Statement: IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. Wear protective gloves/protective clothing/eye protection/face protection. Call a POISON CENTER or doctor/physician if you feel unwell. IF ON SKIN: Gently wash with plenty of soap and water. IF SWALLOWED: rinse mouth. Do NOT induce vomiting. Wear eye protection/face protection. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician. IF exposed: Call a POISON CENTER or doctor/physician. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Avoid release to the environment. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Ground/Bond container and receiving equipment. WARNING: The information provided on this web site was developed in compliance with European Union (EU) regulations and is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling and use. It is not to be considered as either a warranty or quality specification. |
| MDL Number | MFCD00011418 |
| Health Hazard 2 | GHS H Statement: Toxic if swallowed. Causes severe skin burns and eye damage. Toxic in contact with skin. Causes damage to organs. Fatal if inhaled. Highly flammable liquid and vapor. |
| Flash Point | 14°C |
| Packaging | AcroSeal™ Glass Bottle |
| Health Hazard 1 | GHS Signal Word: Danger |
| Synonym | ammonia,ammonia gas,spirit of hartshorn,nitro-sil,ammoniakgas,ammonia anhydrous,anhydrous ammonia,ammonia, anhydrous,ammoniak,am-fol |
| IUPAC Name | azane |
| Molecular Formula | H3N |
| Formula Weight | 17.03 |
| Specific Gravity | 0.77 |
Thermo Scientific™ USB Dithiothreitol (DTT), 0.1M Solution
Solution is 0.2 μm filtered and dispensed into vials.
Applied Biosystems™ DS-30 Matrix Standard Kit (Dye Set D)
This Matrix Standard Set is used to generate the 'multicomponent matrix' required when analyzing fluorescent dye-labeled DNA fragments.
Applied Biosystems™ DS-31 Matrix Standard Kit (Dye Set D)
Suitable for Dye Set D spectral calibration, on ABI PRISM™ Analyzers: 3100-Avant™, 3100, and 3730. Supports 4-Dye fragment analysis applications.
Applied Biosystems™ DS-33 Matrix Standard Kit (Dye Set G5)
Software for these instruments uses the multicomponent matrix to automatically analyze the five different colored fluorescent dye-labeled samples.