Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter

Get premium performance and flexibility with the Thermo Scientific™ Orion™ Versa Star Pro™ Meter with pH / ISE, Conductivity and RDO / DO Modules to measure up to 4 channels at once

Overview
Brand: Thermo Scientific™

Manufacturer Part Number: VSTAR92

BENCHTOP MULTIPARAMETER METER SET THERMO SCIENTIFIc Orion(R)Versa Star(R) pH/ISE/temp, con/temp,

UNSPSC: 41115600

Code: 59

Additional Details:
Additional Details: Weight: 8.60000kg



Product Code. 11671509

Quantity Price
1 £ 3480.0 / Each
Estimated Shipment
10-01-2017
Add to basket


Description and Specification

Specification

Description Orion Versa Star Pro Benchtop Meter with VSTAR-ISE pH/mV/ISE/Temperature Module; VSTAR-CND Conductivity/TDS/Resistivity/Salinity/Temperature Module; VSTAR-RD RDO/DO/Temperature Module Kit
Includes Versa Star Pro meter, VSTAR-ISE pH/ISE module, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor, 083005MD Orion polarographic dissolved oxygen sensor, 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit, 011007 Orion 1413µS conductivity standard, 080513 DO maintenance kit, BOD adapter/funnel/stirrer, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Range (pH) -2.000 to 20.000pH
Resolution (pH) 0.1, 0.01, 0.001pH
Accuracy (pH) ±0.002pH
Range (mV) ±2000.0mV
Range (Relative mV) ±2000.0mV
Range (ORP) ±2000.0mV
Resolution (mV) 0.1mV
Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
Range (ISE) 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none
Resolution (ISE) 0.0001 minimum, 1 to 4 significant digits (user selectable)
Accuracy (ISE) ±0.2 mV or ±0.05% of reading whichever is greater
Advanced ISE Functions Timed endpoint, linear point to point, non-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition and subtraction, double known addition and subtraction, single analyte addition and subtraction
Isopotential Point 7.000pH (adjustable), 1.000 ISE (adjustable)
Range (Conductivity) 0.001 µS/cm to 3000 mS/cm
Resolution (Conductivity) 0.001 μS minimum, auto ranging up to 4 significant digits
Accuracy (Conductivity) 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Range (TDS) 0.001 to 200.0 ppm
Resolution (TDS) 0.001 ppm minimum, auto ranging up to 4 significant digits
Accuracy (TDS) 0.5% of reading ±1 digit
TDS Factor Range Linear (0.02 to 9.99)
Range (Salinity) 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Resolution (Salinity) 0.01 psu or 0.01 ppt minimum, auto ranging
Accuracy (Salinity) 0.5% of reading ±1 digit
Salinity Measurement Modes Practical salinity (psu) or natural sea water (ppt)
Range (Resistivity) 2 ohm to 100.0 meg-ohm
Resolution (Resistivity) 1 ohm or 0.1 meg-ohm, auto ranging
Accuracy (Resistivity) 0.5% of reading ±1 digit
Cell Constant 0.001 to 199.9cm-1
Temperature Compensation Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (Metric) Reference 5, 10, 15, 20, 25°C
Range (Polarographic DO) 0.00 to 90.00mg/L
Resolution (Polarographic DO) 0.01, 0.1mg/L
Accuracy (Polarographic DO) ±0.2mg/L or ±2% of reading, whichever is greater
Range (RDO) 0.00 to 50.00mg/L
Resolution (RDO) 0.01, 0.1mg/L
Accuracy (RDO) ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L
Percent Saturation Range (Polarographic DO) 0.0 to 600.0 % saturation
Percent Saturation Resolution (Polarographic DO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (Polarographic DO) ±2 % saturation or ±2% of reading whichever is greater
Percent Saturation Range (RDO) 0.0 to 500.0 % saturation
Percent Saturation Resolution (RDO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (RDO) ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation
Barometric Pressure Correction 400 to 850mmHg, automatic using built-in barometer or manual entry
Pressure Range 400 to 850mmHg
Pressure Resolution 0.1mmHg
Accuracy (Barometer) ±6mmHg
Salinity Factor 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity
Calibration pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option, dissolved oxygen and temperature
Calibration Points (pH) 1 to 6
Calibration Points (ISE) 1 to 6
Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity) Up to 6
Calibration Modes Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.1°C
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Channels 4 - customizable with modules
Display Type Color graphic LCD with user-customizable options
Backlight Option Yes
Keypad Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement Modes pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature; conductivity, TDS, salinity or resistivity with temperature; dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management Details Transfer single, range or all data points to printer or computer
Data Points 2000 with date and time stamp
Log Function Type Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
Memory Non-volatile memory preserves data log, calibration log and meter settings
Alarm Output Set point alarm, high/low limit alarm, calibration due alarm
Methods 10 per channel with password protection
Languages English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Inputs BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
Outputs USB (2), RS232
Power Supply Universal AC adapter (included)
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
IP Rating IP-54
Certifications/Compliance CE, TUV 3-1, FCC Class A
Temperature (Metric) Operating 5° to 45° C (ambient)
Relative Humidity Range 5 to 85 %, non-condensing
Dimensions (L x W x H) 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Weight (Metric) 1.2kg, modules add 0.2kg each
Model Orion Versa Star Pro 90 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Benchtop Meter
Warranty 3 year meter and module warranty

Large, color graphic LCD display:

  • Informative display shows readings, connections, time, date, sample ID, user ID and calibration information.
  • Five modules customize the four channels as needed.
  • Display includes plain language screen prompts and soft keys that update for easy selection.
  • Multilanguage interface supports English, Spanish, French, Italian, German and Chinese.

Features:

  • Nonvolatile memory holds up to 2,000 data points with time and date stamp
  • Two USB and RS232 ports allow easy data transfer and meter software updates
  • Data analysis software transfers stored results or displays readings in real time
  • Direct control of two Orion Star stirrer probes (096019, sold separately) allows you to mix samples without a stir plate
  • Electrode arm and newly designed probe holder make it easier to maintain and place probes into samples
  • Universal power adapter works with almost every AC power source
  • IP54-rated housing handles splashes

VERSA STAR pH/ISE Module, VSTAR-ISE:

  • pH, concentration using ISE, mV, relative mV (RmV) or ORP with temperature measurements
  • Up to six-point pH and ISE calibrations with editing to correct individual points without a full recalibration
  • Advanced ISE features including incremental techniques, timed end point, linear or point-to-point, non-linear selectable auto-blank, low-concentration range stability and ISE ID

VERSA STAR Conductivity Module, VSTAR-CND:

  • Conductivity, TDS, salinity or resistivity with temperature measurements
  • Selectable conductivity reference temperatures of 5, 10, 15, 20 or 25 °C with linear, non-linear nLFn, non-linear nLFu and EP curve options
  • Choice of practical salinity or natural sea water curves for salinity

VERSA STAR Dissolved Oxygen/RDO Module, VSTAR-RD:

  • Dissolved oxygen as percent saturation or concentration with temperature measurements
  • Flexibility to use Orion polarographic or RDO optical dissolved oxygen probes with automatic meter recognition of the probe type
  • Calibration options for water-saturated air, air-saturated water, custom value using a Winkler titration or zero point
  • Compensates automatically for temperature and barometric pressure with option for automatic or manual salinity correction

Includes:

  • VSTAR90 meter and VSTAR92 meter kit: VSTAR-ISE pH/ISE module, one VSTAR-CND conductivity module and one VSTAR-RD DO/RDO module
  • VSTAR91 meter and VSTAR93 meter kit: two VSTAR-ISE pH/ISE modules, one VSTAR-CND conductivity module and one VSTAR-RD DO/RDO module

Documentation

Technical documents

Videos