Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter

Get premium performance and flexibility with the Thermo Scientific™ Orion™ Versa Star Pro™ Meter with pH / ISE, Conductivity and RDO / DO Modules to measure up to 4 channels at once

Overview
Brand: Thermo Scientific™

Manufacturer Part Number: VSTAR91

VERSA STAR2PH/ISE COND RDO/DO MOD

UNSPSC: 41115603

Code: 59

Additional Details:
Additional Details: Weight: 1.36080kg



Product Code. 11661509

Quantity Price
1 £ 3490.0 / Each
Estimated Shipment
03-04-2017
Add to basket


Description and Specification

Specification

Advanced ISE Functions Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition and subtraction, double known addition and subtraction, single analyte addition and subtraction
Methods 10 per channel
Description Orion Versa Star Pro benchtop meter with two pH/ISE/mV modules, conductivity/TDS/salinity/resistivity module, RDO/DO module and stand
Includes Versa Star Pro meter, two VSTAR-ISE pH/ISE modules, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Range (ISE) 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none
Isopotential Point 7.000pH (adjustable), 1.000 ISE (adjustable)
Range (Conductivity) 0.001 µS/cm to 3000 mS/cm
Percent Saturation Resolution (RDO) 0.1, 1 % saturation
Accuracy (Barometer) ±6mmHg
Calibration Points (ISE) 1 to 6
Backlight Option Yes
Data Points 2000 with date and time stamp
Resolution (mV) 0.1mV
Cell Constant 0.001 to 199.9cm-1
Percent Saturation Resolution (Polarographic DO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (Polarographic DO) ±2 % saturation or ±2% of reading whichever is greater
Calibration Modes Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Range (mV) ±2000.0mV
Alarm Output Set point alarm, high/low limit alarm, calibration due alarm
Outputs USB (2), RS232
Accuracy (ISE) ±0.2 mV or ±0.05% of reading whichever is greater
Resolution (Resistivity) 1 ohm or 0.1 meg-ohm, auto ranging
Resolution (Polarographic DO) 0.01, 0.1mg/L
Accuracy (Polarographic DO) ±0.2mg/L or ±2% of reading, whichever is greater
Resolution (Temperature) 0.1°C, 0.1°F
Temperature Selection Manual or automatic with ATC temperature probe
Display Type Color graphic LCD with user-customizable options
Languages English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
IP Rating IP-54
Relative Humidity Range 5 to 85 %, non-condensing
Dimensions (L x W x H) 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Resolution (ISE) 0.0001 minimum, 1 to 4 significant digits (user selectable)
Range (Salinity) 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Resolution (Salinity) 0.01 psu or 0.01 ppt minimum, auto ranging
Resolution (pH) 0.1, 0.01, 0.001pH
Accuracy (pH) ±0.002pH
Measurement Modes pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature; conductivity, TDS, salinity or resistivity with temperature; dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
Log Function Type Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
Inputs 2 BNC (pH or ISE), 2 x 8-pin Mini-DIN (temperature), 2 reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
Resolution (Conductivity) 0.001 μS minimum, auto ranging up to 4 significant digits
Accuracy (Salinity) 0.5% of reading ±1 digit
Barometric Pressure Correction 400 to 850mmHg, automatic using built-in barometer or manual entry
Calibration Points (pH) 1 to 6
Salinity Factor 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity
Calibration Points (Conductivity) Up to 6
Data Management Details Transfer single, range or all data points to printer or computer
Weight (Metric) 1.2kg, modules add 0.2kg each
Accuracy (Resistivity) 0.5% of reading ±1 digit
Pressure Range 400 to 850mmHg
Channels 4 - customizable with modules
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
Temperature Compensation Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Range (Polarographic DO) 0.00 to 90.00mg/L
Range (pH) -2.000 to 20.000pH
Percent Saturation Range (Polarographic DO) 0.0 to 600.0 % saturation
Pressure Resolution 0.1mmHg
Calibration pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option, dissolved oxygen and temperature
Accuracy (Temperature) ±0.1°C
Power Supply Universal AC adapter (included)
Range (Relative mV) ±2000.0mV
Warranty 3 year meter and module warranty
Accuracy (TDS) 0.5% of reading ±1 digit
TDS Factor Range Linear (0.02 to 9.99)
Range (Resistivity) 2 ohm to 100.0 meg-ohm
Temperature (Metric) Reference 5, 10, 15, 20, 25°C
Range (RDO) 0.00 to 50.00mg/L
Resolution (RDO) 0.01, 0.1mg/L
Percent Saturation Range (RDO) 0.0 to 500.0 % saturation
Percent Saturation Relative Accuracy (RDO) ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation
Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
Temperature (Metric) Operating 5° to 45° C (ambient)
Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
Accuracy (Conductivity) 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Range (TDS) 0.001 to 200.0 ppm
Resolution (TDS) 0.001 ppm minimum, auto ranging up to 4 significant digits
Salinity Measurement Modes Practical salinity (psu) or natural sea water (ppt)
Accuracy (RDO) ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L
Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
Temperature Probe Calibration 1 point temperature offset calibration
Keypad Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Memory Non-volatile memory preserves data log, calibration log and meter settings
Certifications/Compliance CE, TUV 3-1, FCC Class A
Range (ORP) ±2000.0mV

Large, color graphic LCD display:

  • Informative display shows readings, connections, time, date, sample ID, user ID and calibration information.
  • Five modules customize the four channels as needed.
  • Display includes plain language screen prompts and soft keys that update for easy selection.
  • Multilanguage interface supports English, Spanish, French, Italian, German and Chinese.

Features:

  • Nonvolatile memory holds up to 2,000 data points with time and date stamp
  • Two USB and RS232 ports allow easy data transfer and meter software updates
  • Data analysis software transfers stored results or displays readings in real time
  • Direct control of two Orion Star stirrer probes (096019, sold separately) allows you to mix samples without a stir plate
  • Electrode arm and newly designed probe holder make it easier to maintain and place probes into samples
  • Universal power adapter works with almost every AC power source
  • IP54-rated housing handles splashes

VERSA STAR pH/ISE Module, VSTAR-ISE:

  • pH, concentration using ISE, mV, relative mV (RmV) or ORP with temperature measurements
  • Up to six-point pH and ISE calibrations with editing to correct individual points without a full recalibration
  • Advanced ISE features including incremental techniques, timed end point, linear or point-to-point, non-linear selectable auto-blank, low-concentration range stability and ISE ID

VERSA STAR Conductivity Module, VSTAR-CND:

  • Conductivity, TDS, salinity or resistivity with temperature measurements
  • Selectable conductivity reference temperatures of 5, 10, 15, 20 or 25 °C with linear, non-linear nLFn, non-linear nLFu and EP curve options
  • Choice of practical salinity or natural sea water curves for salinity

VERSA STAR Dissolved Oxygen/RDO Module, VSTAR-RD:

  • Dissolved oxygen as percent saturation or concentration with temperature measurements
  • Flexibility to use Orion polarographic or RDO optical dissolved oxygen probes with automatic meter recognition of the probe type
  • Calibration options for water-saturated air, air-saturated water, custom value using a Winkler titration or zero point
  • Compensates automatically for temperature and barometric pressure with option for automatic or manual salinity correction

Includes:

  • VSTAR90 meter and VSTAR92 meter kit: VSTAR-ISE pH/ISE module, one VSTAR-CND conductivity module and one VSTAR-RD DO/RDO module
  • VSTAR91 meter and VSTAR93 meter kit: two VSTAR-ISE pH/ISE modules, one VSTAR-CND conductivity module and one VSTAR-RD DO/RDO module

Documentation

Technical documents

Videos