Thermo Scientific™ Orion Star™ A215 pH/Conductivity Benchtop Multiparameter Meter

Reliably measure pH, conductivity and temperature with the Thermo Scientific™ Orion™ Star A215 pH / Conductivity Benchtop Meter for advanced lab analysis and interfacing

Brand: Thermo Scientific™

Manufacturer Part Number: STARA2155


UNSPSC: 41115603

Code: 59

Additional Details:
Additional Details: Weight: 1.36080kg

Product Code. 11601469

Quantity Price
1 £1901.38 / Each
Estimated Shipment
Add to basket

Description and Specification


Description Orion Star A215 pH/conductivity benchtop meter kit with ROSS Ultra Triode epoxy-body pH/ATC electrode, DuraProbe 4-cell conductivity sensor, solutions and stand
Item Description Orion Star A215 pH/conductivity benchtop meter kit with ROSS Ultra Triode epoxy-body pH/ATC electrode, DuraProbe 4-cell conductivity sensor, solutions and stand
Range (pH) -2.000 to 20.000pH
Resolution (pH) 0.1, 0.01, 0.001pH
Accuracy (pH) ±0.002pH
Range (mV) ±2000.0mV
Range (Relative mV) ±2000.0mV
Range (ORP) ±2000.0mV
Resolution (mV) 0.1mV
Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
Isopotential Point 7.000pH
Range (Conductivity) 0.001 µS/cm to 3000 mS/cm
Resolution (Conductivity) 0.001 μS minimum, auto ranging up to 4 significant digits
Accuracy (Conductivity) 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Range (TDS) 0.001 to 200.0 ppm
Resolution (TDS) 0.001 ppm minimum, auto ranging up to 4 significant digits
Accuracy (TDS) 0.5% of reading ±1 digit
TDS Factor Range Linear (0.02 to 9.99)
Range (Salinity) 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Resolution (Salinity) 0.01 psu or 0.01 ppt minimum, auto ranging
Accuracy (Salinity) 0.5% of reading ±1 digit
Salinity Measurement Modes Practical salinity (psu) or natural sea water (ppt)
Range (Resistivity) 2 ohm to 100.0 meg-ohm
Resolution (Resistivity) 1 ohm or 0.1 meg-ohm, auto ranging
Accuracy (Resistivity) 0.5% of reading ±1 digit
Cell Constant 0.001 to 199.9cm-1
Temperature Compensation Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (Metric) Reference 5, 10, 15, 20, 25°C
Calibration pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option and temperature
Calibration Points (pH) 1 to 5
Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity) Up to 5
Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.1°C
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Channels 2
Display Type Graphic LCD with backlight
Backlight Option Yes, selectable
Keypad Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement Modes pH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management Details Transfer single, range or all data points to printer or computer
Data Points 2000 with date and time stamp
Log Function Type Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous measure mode
Memory Non-volatile memory preserves data log, calibration log and meter settings
Alarm Output High/low limit alarm, calibration due alarm
Methods 10 per channel with password protection
Languages English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
Inputs BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
Outputs USB, RS232
Power Supply Universal AC adapter (included) or 4 AA batteries (sold separately)
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
Battery Type Four AA (sold separately)
Battery Life 800 hours
IP Rating IP-54
Certifications/Compliance CE, TUV 3-1, FCC Class A
Temperature (Metric) Operating 5° to 45° C (ambient)
Relative Humidity Range 5 to 85 %, non-condensing
Dimensions (L x W x H) 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.)
Weight (Metric) 0.9kg
Model Orion Star A215 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter
Warranty 3 year meter warranty

The Thermo Scientific Orion Star A215 pH/ Conductivity Benchtop Meter is the ideal choice for any lab. Get the information you need quickly and easily from the large, backlit graphic LCD display. Informative display shows individual pH/mV/RmV or conductivity/TDS/salinity/ resistivity results with temperature, or all results at once. Additional helpful information includes electrode status, time, date, sample ID, user ID and calibration. For advanced users, features such as stability and averaging choices provide additional options.
  • Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese
  • Don't miss a reading — AUTO-READ™ locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals
  • Up to five point pH calibration with automatic recognition for USA/NIST and DIN buffers and calibration editing to fix errors without a complete recalibration
  • Selectable cell constant allows for use with 2- or 4-cell conductivity cells
  • For accurate conductivity results, selectable reading reference temperatures of 5°, 10°, 15°, 20° or 25°C with linear, nonlinear, nLFu or EP curve options
  • Choice of practical salinity or natural sea water curves for salinity readings
  • Linear or ISO/EN 27888 curves for TDS
  • Nonvolatile memory holds up to 2000 data points with time and date stamp
  • Easily transfer data and keep meter software up-to-date with the USB and RS232 ports and complimentary data analysis software
  • Mix samples without a stir plate with direct control of the Orion Star stirrer probe (096019, sold separately)
  • Included electrode arm and newly designed probe holder make it easier to maintain and place probes into samples
  • Works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power
  • IP54-rated housing handles splashes and is wall-mountable if table space is a problem