Western Blotting Reagents, Membranes, Supplies

Thermo Scientific™ Pierce™ ECL Western Blotting Substrate

Value-priced, entry-level peroxidase substrate for enhanced chemiluminescence (ECL) that directly replaces costlier products without the need to re-optimize conditions. 50 ML ECL WESTERN BLOTTING SUBSTRATE

GE Healthcare Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls

Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. GE Healthcare Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background. X1 Amersham Protran 0.1um Nitrocellulose 150mm x 4m roll

GE Healthcare Amersham™ Hyperfilm™ ECL

Use with all blue and green light chemiluminescent systems. GE Healthcare Amersham™ Hyperfilm™ ECL is constructed from a clear base coated on both sides with a photographic emulsion that is protected by an anti-scratch layer. X50 Autoradiography film GE Healthcare Amersham

GE Healthcare Amersham™ ECL™ Prime Western Blotting Detection Reagent

Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity.  GE Healthcare Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity. X3 AMERSHAM ECL PRIME, CHEMILUMINESCENT WESTERNblotting detection reagent 3mLStore in Fridge at

NeutrAvidin Protein, Invitrogen™

NeutrAvidin Protein, 31000, from Invitrogen™, 31000, from Invitrogen™ Species Reactivity: ; Applications: ELISA, Immunohistochemistry, In Situ Hybridization (ISH), Western Blot. IMMUNOPURE NEUTRAVIDIN BIOTIN-BINDING PROTEIN, 10re 10mg

Thermo Scientific™ SuperSignal™ West Femto Chemiluminescent Substrate

Ultra-sensitive enhanced chemiluminescent (ECL) HRP substrate for low-femtogram-level detection by Western blot analysis. SUPERSIGNAL WEST FEMTO MAX. SENSITIVITY SUBSTRATE,SuperSignal 200mL Store in fridge at 4C

Thermo Scientific™ Pierce™ Western Blotting Filter Papers

Pre-cut cotton sheets for wet or semi-dry, passive or electrophoretic transfer of proteins from polyacrylamide gels to PVDF, nitrocellulose, or other membranes. Extra Thick Western Blotting Filter Paper,8.5 x 9cm, VE=50 St.

Thermo Scientific™ Restore™ Western Blot Stripping Buffer

Safely and effectively remove primary and secondary antibodies from nitrocellulose and PVDF membranes to allow chemiluminescent Western blots to be reprobed. 5 LT RESTORE(TM) WESTERN BLOT STRIPPING BUFFER 5L

Invitrogen™ Novex™ iBlot™ 2 Nitrocellulose Transfer Stacks

Used to transfer proteins with the iBlot 2 Gel Transfer Device 10 stacks, iBlot 2 Transfer Stacks,nitrocellulose, mini

Invitrogen™ Molecular Probes™ MitoSOX™ Red Mitochondrial Superoxide Indicator, for live-cell imaging

For live-cell imaging X10 Mitosox red mitochondrial supe 50µg Store atMitoSOX Red reagent is a novel fluorogenic dye

Merck™ Immobilon™ FL PVDF Transfer Membranes

Designed specifically for Western blots and protein sequencing. EMD Millipore Immobilon™-FL PVDF Transfer Membranes are plain surfaced with 0.45μm pores and have lower background fluorescence than other membranes. Available in 10cm and 20cm squares and a 3.75m roll. 10ST Immobilon-FL 20x20cm sheet PVDF 0.45um

GE Healthcare Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls

Use for the best results with fluorescence Western blotting detection applications. GE Healthcare Life Sciences™ Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background. X1 Amersham Protran Premium 0.2um Nitrocellulose 150mm x 4m roll

Merck™ Immobilon™-P PVDF Transfer Membranes

Optimized for binding proteins transferred from a variety of gel matrices. EMD Millipore Immobilon™-P PVDF Transfer Membranes have superior handling, staining, and resistance than nitrocellulose. For use with Western blots and protein sequencing. Available in sheets or rolls. X10 Immobilon-P 9 x 12cm sheet PVDF .45um

Invitrogen™ Invitrolon Novex Invitrolon PVDF/Filter Paper Sandwich

Pre-cut and pre-assembled and ready for protein blotting/transfer FILTER PAPER SANDWICH INVITROGEN(TM) INVITROLON(TM) pre-cut, pre-assembled high quality membrane

Thermo Scientific™ Restore™ Plus Western Blot Stripping Buffer

Remove high-affinity antibodies from membranes so they can be reprobed and detected with chemiluminescent substrates. X2 RESTORE(TM) PLUS WESTERN BLOT STRIPPING BUFFER30mL

Thermo Scientific™ Blocker™ Casein Blocking Buffers

Block membranes, plates and other samples with these ready-to-use PBS or TBS solutions of purified casein for Western blot, ELISA and other detection methods. 100mL Blocker Casein in TBS

Thermo Scientific™ CL-XPosure™ Film (X-Ray Film)

Capture results of ECL-based Western blots and other chemiluminescent protein or nucleic acid assays using this economically priced, clear-blue X-ray film. X100 X ray film Thermo Scientific Pierce CL-XPosur

GE Healthcare Amersham™ Hybond™ P 0.45μm PVDF Membrane

Use for chemiluminescent and fluorescent detection methods for proteins of > Mr 20 000. GE Healthcare Life Sciences™ Amersham™ Hybond™ P 0.45μm PVDF Membrane is a 0.45 μm pore size hydrophobic membrane, with high physical strength, highly suitable for stripping and reprobing. X5 Amersham Hybond 0.45um PVDF 300mm x 600mm sheet

GE Healthcare Amersham™ Hybond™ -N+ Membranes

Use for the highest sensitivity in DNA and RNA blotting. GE Healthcare Life Sciences™ Amersham™ Hybond™ -N+ Membrane is a positively charged nylon membranes for use with radioactive and nonradioactive chemiluminescence and chemifluorescence detection. X20 Blotting membrane GE Healthcare Amersham

Thermo Scientific™ Pierce™ PVDF Membranes

Enable high protein and nucleic acid binding capacity with sheets and rolls of high-quality polyvinylidene difluoride (PVDF) membrane. X10 PVDF Transfer Membrane, 0.45µm 100mm x 100mm

Invitrogen™ Novex™ Bolt™ Welcome Pack + iBlot™ 2 System

A complete protein separation-to-western blot solution by combining a Bolt Welcome Pack A with the iBlot 2 Gel Transfer Device and iBlot 2 Transfer Stack (nitrocellulose, regular size) in lieu of one box of Bolt gels Bolt Welcome Pack + iBlot 2 System

Thermo Scientific™ SuperSignal™ West Pico PLUS Chemiluminescent Substrate

An enhanced chemiluminescent (ECL) horseradish peroxidase (HRP) substrate that enables picogram- to high femtogram-level protein detection by western blot analysis SUPERSIGNAL WEST PICO PLUS

Invitrogen™ Novex™ XCell™ SureLock™ Mini-Cell and XCell II™ Blot Module

Quickly and easily run and blot Novex minigels SURELOCK KIT WITH BLOT MODULE 0

GE Healthcare Amersham™ Protran™ NC Nitrocellulose Membranes: Sheets

Use for Western blots, dot-blot assays, and other protein or nucleic acid methods. GE Healthcare Amersham™ Protran™ NC Nitrocellulose Membranes: Sheets offer excellent sensitivity, resolution, and low background. X25 Amersham Protran 0.45um Nitrocellulose 80mm x90mm sheets

Invitrogen™ Novex™ iBlot™ Nitrocellulose Transfer Stack

iBlot Transfer Stacks are used to transfer proteins X3 Transfer stack iBlot(R) mini nitrocellulose

Thermo Scientific™ 1-Step™ TMB-Blotting Substrate Solution

Ready-to-use blue TMB peroxidase (HRP) substrate specially formulated for chromogenic detection in Western blot and IHC experiments. 1-STEP TMB-BLOTTING, 250 MLat 4C

Molecular Probes™ BlockAid™ Blocking Solution

BlockAid™ Blocking Solution BLOCKAID(TM) BLOCKING SOLThe BlockAid reagent is a protein-based blocking

Thermo Scientific™ Pierce™ TMB Substrate Solution

A ready-to-use substrate system containing 3.3', 5.5'-tetramethylbenzidine (TMB) 100 ML TMB SUBSTRATE SOLUTION 100ML STORE INfridge at 4C

Invitrogen™ Mini Gel Tank and Blot Module Set

Provides all of the necessary devices for protein separation and Western blotting using Novex™ gels, NuPAGE™ gels, and Bolt™ Bis-Tris Plus gels Mini Gel Tank and Blot Module Set

Merck™ Immobilon™ Western Chemiluminescent HRP Substrate (ECL)

Provides high sensitivity over a broad detection range at an economical price X2 IMMOBILON WESTERN CHEMILUM HRP SUBSTRATE 50ml

  spinner