Filtered Search Results
Search results for "guard cartridge thermo"
Thermo Scientific™ Acclaim™ Phenyl-1 HPLC Columns
Use for high-resolution analysis of aromatic analytes, including glucocorticosteroids, estrogens, fat-soluble vitamins, and phospholipids.
Pore Size | 120 Å |
---|---|
Carbon Load | 13% |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L11 |
Thermo Scientific™ Hypersil™ MOS C8 HPLC Columns
Use as a general-purpose C8 phase for acidic and neutral analytes.
Pore Size | 120 Å |
---|---|
Carbon Load | 6.5% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
Product Line | Hypersil Classical |
USP Type | L7 |
Thermo Scientific™ Acclaim™ Surfactant HPLC Columns
Use for outstanding separation of anionic, nonionic, and cationic surfactants with ELSD and RI detectors.
Pore Size | 120 Å |
---|---|
Carbon Load | 12% |
Stationary Phase | Proprietary |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil GOLD™ Cyano HPLC Columns
Alternate selectivity with lower hydrophobicity. Use these HPLC columns for normal and reversed phase separations.
Pore Size | 175 Å |
---|---|
Carbon Load | 4% |
Stationary Phase | Cyano (CN) |
Temperature | 60°C |
Phase | Normal and Reversed Phase |
Endcapped | Yes |
Column Type | Mixed Mode |
pH | 2 to 8 |
Surface Area | 220 m²/g |
USP Type | L10 |
Thermo Scientific™ Syncronis™ Amino HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Thermo Scientific™ Syncronis™ Amino LC Columns.
Pore Size | 100 Å |
---|---|
Carbon Load | 4% |
Stationary Phase | Amino (NH2) |
Temperature | 60°C |
Phase | Reversed Phase, Normal Phase, Ion Exchange, HILIC |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Mixed Mode |
pH | 2 to 8 |
Surface Area | 320 m²/g |
Max. Pressure | 5800 psi (400 bar) |
USP Type | L8 |
Thermo Scientific™ MAbPac™ HIC-20 HPLC Columns
Use this column to separate monoclonal antibodies (mAbs), mAb fragments and oxidized variants by hydrophobic interaction chromatography (HIC).
Pore Size | 1000 Å |
---|---|
Particle Size | 5 μm |
Temperature | 60°C |
Phase | Hydrophobic Interaction |
Packing Material | Spherical, High Purity Silica |
pH | 2 to 9 |
Product Line | MAbPac |
Thermo Scientific™ Accucore™ 150 Amide HILIC HPLC Columns
Designed for the separation of hydrophilic biomolecules in HILIC mode—an excellent choice for glycan separations.
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ GuardGOLD™ Capillary Columns
Protect your analytical column from damage and contamination from nonvolatile materials.
Thermo Scientific™ Acclaim™ Mixed Mode HILIC-1 HPLC Columns
Get all the advantages of reversed-phase and hydrophilic interaction liquid chromatography (HILIC) in one column with the Thermo Scientific™ Acclaim™ Mixed-Mode HILIC-1 column.
Pore Size | 120 Å |
---|---|
Stationary Phase | Hydrophobic Alkyl Chain with a Diol Group |
Temperature | 50°C |
Phase | Reversed Phase and HILIC |
Endcapped | Proprietary |
Column Type | Mixed Mode |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | N/A |
Thermo Scientific™ Acclaim™ Mixed Mode WAX-1 HPLC Columns
When you need powerful selectivity control for the separation of anionic molecules, use Thermo Scientific™ Acclaim™ Mixed-Mode WAX-1 LC columns.
Pore Size | 120 Å |
---|---|
Phase | Reversed Phase, Ion Exchange, HILIC |
Column Type | Mixed Mode |
pH | 2.5 to 7.5 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | L78 |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns
Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
Pore Size | 120 Å |
---|---|
Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
Temperature | 50°C |
Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
Endcapped | Proprietary |
Column Type | Mixed Mode |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | L85 |
Thermo Scientific™ Accucore™ XL C8 HPLC Columns
Improve laboratory productivity using Thermo Scientific™ Accucore™ XL C8 Columns.
Pore Size | 80 Å |
---|---|
Particle Size | 4 μm |
Carbon Load | 4% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 130 m²/g |
Max. Pressure | 8700 psi (600 bar) |
USP Type | L7 |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |