Multiparameter Meters
Filtered Search Results
Fisherbrand™ accumet™ AB200 Benchtop pH/Conductivity Meters
Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisherbrand accumet AB200 pH/conductivity meter combines the benefits of a pH meter and conductivity meter in one easy to use, reliable measurement system. The large backlit display offers great visibility in laboratory environments.
| Range (Resistivity) | 2 W to 20 MW |
|---|---|
| Resolution (pH) | 0.1/0.01/0.001 |
| Cell Constant | 0.010 to 10.000 |
| Range (pH) | -2 to 20 |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0 to 80 ppt |
| Data Management Details | Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format |
| Display Type | LCD |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±1% FS |
| Resolution (mV) | 0.1mV |
| Data Points | 500 |
| Inputs | BNC, ATC |
| Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Accuracy (mV) | ±0.2 mV |
| Warranty | 3 Years |
| Temperature Accuracy | ±0.3°C |
| Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Resolution (Conductivity) | 0.01/0.1μS, 0.001/0.01/0.1mS |
| Range (Conductivity) | 0 μS to 500 mS |
| Accuracy (Resistivity) | ± 1% full scale |
| Range (TDS) | 0 ppm to 500 ppt (at TDS factor 1) |
| Resolution (TDS) | 0/0.1ppm, 001/01/0.1ppt |
| Accuracy (TDS) | ± 1% full scale |
| Outputs | RS232 (phono plug), mini-B USB, stirrer |
| Frequency | 50/60Hz |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Range (mV) | ±2000 mV |
| Temperature Resolution | 0.1°C |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE Benchtop Multiparameter Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and ultimate flexibility with our benchtop meter with pH/ISE module for pH, ion concentration, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP54 |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and flexibility with our benchtop meter with pH and conductivity modules for simultaneous pH, conductivity, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | Up to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH (adjustable) |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
For the ultimate flexibility, combine the Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules with up to four measurement modules to build your ideal system.
METTLER TOLEDO™ SevenExcellence™ S470 pH/Conductivity Benchtop Meter
The S470 meter measures pH, conductivity, resistivity, redox/ORP, TDS, salinity, and ISFET. It can be expanded with additional modules to measure dissolved oxygen, BOD, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel file, or LIMS system.
| Range (Resistivity) | 0.01 to 100 Mohm/cm |
|---|---|
| Resolution (pH) | 0.001/0.01/0.1 |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.001 to 1 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0 to 999999mg/L |
| Range (Salinity) | 0 to 80 ppt |
| Display Type | TFT |
| Resolution (Salinity) | 0.001 to 1 |
| Accuracy (Conductivity) | ±0.5% |
| Resolution (mV) | 0.1/1mV |
| Data Points | 20,000 |
| Calibration Points (Conductivity) | 13 Pre defined and 20 user defined standard |
| Accuracy (mV) | ±0.1mV |
| Temperature Accuracy | ±0.1°C |
| Calibration Points (ISE) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
| Resolution (Resistivity) | 0.001 to 1 |
| Resolution (Conductivity) | 0.001μS/cm to 2000mS/cm |
| Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
| Range (TDS) | 0.001 mg/L to 1000 g/L |
| Resolution (TDS) | 0.001 to 1 |
| Outputs | RS232, USB-A, USB-B, LAN, Mini-LTW, Mini-DIN, BNC, Cinch/RCA |
| Calibration Points (pH) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
| Temperature Range (Metric) | -30°C to +130°C |
| Range (mV) | -2000 to 2000 mV |
| Temperature Resolution | 0.1°C |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850mmHg |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Power Supply | Universal AC adapter (included) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6 mmHg |
| Range (ORP) | ±2000.0 mV |
| Pressure Resolution | 0.1mmHg |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | Up to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Oakton™ pH 700, CON 700, pH-CON 700 pH/Conductivity Benchtop Meters, Measures conductivity, TDS and temperature
An affordable way to take consistent, accurate conductivity measurements in your laboratory.
| Warranty | 3 Years |
|---|---|
| Temperature Compensation | Automatic or manual from 0° to 100°C |
| Display Type | LCD |
| Voltage | 120/240 V |
WTW™ inoLab™ Multiparameter Digital Benchtop Meters
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Obtain uncompromised measuring accuracy of digital measurements of pH, ORP, dissolved oxygen (optical), BOD, conductivity and turbidity in the lab using the WTW™ inoLab™ Multiparameter Digital Benchtop Meters.
| Resolution (pH) | 0.1/0.01/0.001 |
|---|---|
| Range (pH) | -2 to 20.001 |
| Width (Metric) | 24 cm |
| Accuracy (pH) | ±0.005 |
| Power Supply | 4 x 1.5V AA type batteries |
| Range (Salinity) | 0 to 70 ppt |
| Data Management Details | 500 Manual/5000 automatic with time/date stamp |
| Display Type | LCD |
| Resolution (Salinity) | 3 Significant digits |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±0.05% of reading |
| Resolution (mV) | 0.1mV |
| Resolution (DO) | 3 Significant digits |
| Certifications/Compliance | cETLus, CE |
| Calibration Points (Conductivity) | 1 |
| Shipping Weight (Metric) | 8 kg |
| Height (Metric) | 19 cm |
| Accuracy (mV) | ±0.3 or 0.05% of reading |
| Warranty | 3 Years |
| Temperature Accuracy | ±0.1 |
| Accuracy (DO) | ±0.05% of reading |
| Resolution (Resistivity) | 3 Significant digits |
| Resolution (Conductivity) | 3 Significant digits |
| Range (Conductivity) | 0 μS to 1000 mS |
| Range (TDS) | 0 to 1999 mg/L |
| Resolution (TDS) | 3 Significant digits |
| Dimensions (L x W x H) | 24 W x 19 Hcm |
| Product Type | Digital benchtop multiparameter |
| Depth (Metric) | 8 cm |
| Model | inoLab Multi 9310 IDS |
| Outputs | Mini USB |
| Frequency | 50/60Hz |
| Calibration Points (pH) | 1 to 5 |
| Temperature (Metric) Operating | 0°C to 50°C |
| Range (mV) | ±1200 mV |
| Range (DO) | 0 to 90mg/L |
| Temperature Resolution | 0.1 |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Jenway™ Bench Meters
Use this versatile benchtop meter for a variety of applications. Jenway™ Bench Meters are ideal for routine analysis.
| Height (Metric) | 55 mm |
|---|---|
| Electrical Requirements | 9VAC ±10% at 50/60Hz |
| Temperature Accuracy | ±0.5°C |
| Length (Metric) | 210 mm |
| Voltage | 9 V |
| Frequency | 50/60Hz |
| Temperature Resolution | 0.1°C |
Thermo Scientific™ Eutech™ CON 2700 Conductivity Meter
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Thermo Scientific™ Eutech™ PC 2700 Multi-parameter Meter
Measure multiple parameters in a cost-effective and convenient way by using only one Eutech™ multi-parameter meter.
| Outputs | RS232 |
|---|---|
| Range (pH) | -2 to 20 |
Thermo Scientific™ Eutech™ Ion 2700 Meter
Quick and easy measurement with this ion-selective meter.
| Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
|---|---|
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | 2 to 8 |
| Resolution (pH) | 0.1/0.01/0.001 |
| Measurement Modes | pH,Ion,Redox |
| Range (pH) | -2 to 20 |
| Range (Concentration) | 0.001 to 19999 ppm (±2000 mV) |
| Accuracy (ORP) | ±0.2 mV |
| Resolution (ISE) | 2 or 3 digits |
| Accuracy (pH) | ±0.002 + 1 LSD |
| Power Supply | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
| Includes | Integral Electrode Holder & 100/240 VAC Adapter and RS232 cable |
| Calibration Points | Up to 6 preset or 5 custom |
| Temperature Compensation | ATC / MTC (0 to 100 °C) (pH only) |
| Outputs | RS232 |
| Temperature Range (English) | 32.0°F to 212.0°F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Temperature Range (Metric) | 0.0°C to 100.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Range (DO) | ±2000.0 mV |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Resolution (ORP) | 0.1 mV |
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Range (Resistivity) | 1.0Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (30 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 3 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | ±0.5% reading |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Resolution (Resistivity) | 0.1 Ωminimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Thermo Scientific™ Orion™ Pro Star PD216 pH/ion and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration, dissolved oxygen, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PD216 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
|---|---|
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Dissolved Oxygen (mg/L),Dissolved Oxygen (% Saturation),Temperature,Barometric Pressure |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
| Range (pH) | -2 to 20 |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Calibration | pH, ORP, Ion Concentration, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |