Gloves
Protective gloves and sleeves available in an array of styles and materials for applications such as lab, electrical, medical, and cleanroom work. Protects against hazardous substances, extreme temperatures, impact, sharp objects, and more.
Selection of the appropriate hand protection is based on the hazards workers encounter, such as skin absorption of harmful substances, severe cuts, lacerations, abrasions, punctures, burns, and harmful temperature extremes.
Disposable Gloves
Disposable gloves are typically made from materials such as latex, nitrile, neoprene, butyl, vinyl or specialty formulations that offer some form of chemical resistance. Their thinner construction, like what is found in exam gloves or finger cots, enhances touch sensitivity for tasks involving fine motor skills. They are mostly ambidextrous, but in some applications (i.e., cleanroom gloves) they are pair packed. They are available sterile or non-sterile.
Reusable Gloves
Like disposable gloves, reusable gloves come in a variety of materials and styles designed to handle more demanding hazards. Unlike disposables, reusables can be constructed of one or more materials or fabrics that offer enhanced hand protection.
- Work gloves and mechanics’ gloves may have a soft inner lining and an outer layer of heavier cloth, leather, or synthetic material with reinforced palms or knuckles
- Chemical-resistant gloves may be “dipped” or coated with a layer of nitrile, neoprene, or other materials
- Cut-resistant gloves may be woven of specialty fibers that afford cut or puncture resistance; some styles can be worn underneath other gloves to offer dual protection
- Firefighting, rescue, and tactical gloves may include layers to protect wearers from punctures or extreme temperatures
Other Hand Protection Options
Other reusable glove designs are available for handling more specialized hazards:
- Cold-resistant gloves
- Heat-resistant gloves
- Welding and electrical safety gloves
- Dry box gloves
Filtered Search Results
Ansell AlphaTec™ NRL RABS and Isolator Gloves - 20 mil
Translucent, unlined gloves are constructed of latex and provide defense against tears, abrasions, cuts, and punctures.
| Length (Metric) | 813 mm |
|---|---|
| Size | 10 |
| EN388 Standard | 2020X |
| Color | Natural |
| Length (English) | 32 in. |
| Material | Latex |
| Hand | Specific |
| Thickness (Metric) | 0.51 mm |
| EN ISO 374-1 | Type A |
| Certifications/Compliance (Europe) | CE 0493, EN 374_2003 Microorganism, EN 420:2003 + A1:2009 |
| EN ISO 374-1 CHEMICAL LETTER CODES | KLNOPT |
| Product Type | Dry Box Gloves |
| Thickness (English) | 20 mil |
| Latex Free | No |
Ansell AlphaTec™ 55-301 Neoprene Isolator Gloves
Neoprene RABS/isolator gloves provide chemical resistance against most acids, alcohols, oils, lubricants and hydrocarbons, offering physical protection against abrasions and cuts or punctures.
| Grip Design | Smooth |
|---|---|
| Length (Metric) | 71 cm |
| Port Size (Metric) | 17.8 cm |
| Color | Black |
| Length (English) | 28 in. |
| Material | Neoprene Polymer |
| Sterility | Non-sterile |
| Hand | Ambidextrous |
| Thickness (Metric) | 0.50 mm |
| Series | AlphaTec™ |
| Certifications/Compliance (Europe) | CE 0493, EN 420:2003, A1:2009, Cat III, EN 388:2100A, EN ISO 374-1:2016 Type A - ACJKL, EN ISO 374-5:2016 VIRUS |
| Product Type | Isolator, RABS Gloves |
| Thickness (English) | 20 mil |
| Port Size (English) | 7 in. |
| Latex Free | Yes |
| Glove Cuff Style | Beaded |
Ansell BioClean™ Nitrile Sterile RABS/Isolator Gloves
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Sterile RABS/isolator gloves are manufactured from nitrile with low levels of particles and excellent ESD properties. Designed for use in injectable manufacturing and pharmaceutical production areas.
| Thickness (Metric) | 0.50 mm |
|---|---|
| Grip Design | Smooth |
| Length (Metric) | 84 cm |
| Size | 9.75 |
| Thickness (English) | 20 mil |
| Color | White |
| Cleanroom Class | Class 10 (ISO 4) |
| Length (English) | 33 in. |
| Latex Free | Yes |
| Material | Nitrile |
| Certifications/Compliance | ASTM D6978 |
Ansell BioClean™ Nitrile Cleanroom RABS/Isolator Gloves
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
BioClean™ Nitrile Clean RABS/Isolator Gloves are manufactured from nitrile with incredibly low levels of particles and excellent ESD properties. Designed for use in injectable manufacturing and pharmaceutical production areas, our CGL series of gloves are cleanroom processed and packed.
| Length (Metric) | 84 cm |
|---|---|
| Size | 9.75 |
| Color | White |
| Length (English) | 33 in. |
| Latex Free | Yes |
Ansell AlphaTec™ 55-302 Neoprene Isolator Gloves
Neoprene RABS and Isolator gloves provide physical protection and chemical resistance against most acids, alcohols, oils, lubricants and hydrocarbons
Ansell AlphaTec™ 55-306 Neoprene Isolator Gloves
Neoprene isolator gloves are designed to guard against aggressive chemicals in medium-duty environments.
Ansell AlphaTec™ 55-100 NRL RABS and Isolator Gloves
Gloves provide effective protection for medium duty physical environments, especially for defense against abrasions and tears. Constructed of 0.51 mm latex to ensure maximum dexterity in crucial applications.
| Content And Storage | When not in use store in a dark, dry environment in original packaging |
|---|---|
| EN388 Standard | 2020X |
| Color | Natural |
| Material | Latex |
| For Use With (Application) | Medium Duty Environments |
| Hand | Specific |
| Thickness (Metric) | 0.51 mm |
| Series | 55-100 |
| EN ISO 374-1 | Type A |
| Certifications/Compliance (Europe) | CE 0493, EN 420:2003 + A1:2009 |
| EN ISO 374-1 CHEMICAL LETTER CODES | KLNOPT |
| For Use With (Equipment) | Isolator Glove Boxes |
| Product Type | Isolator, RABS Gloves |
| Thickness (English) | 20 mil |
| Latex Free | No |
Ansell AlphaTec™ 55-303 Neoprene Isolator Gloves
Neoprene RABS and Isolator gloves provide physical protection and chemical resistance against most acids, alcohols, oils, lubricants and hydrocarbons
Ansell AlphaTec™ 55-308 Neoprene Isolator Gloves
Neoprene RABS and Isolator gloves provide physical protection and chemical resistance against most acids, alcohols, oils, lubricants and hydrocarbons
Ansell AlphaTec™ NRL RABS and Isolator Gloves - 30 mil
Translucent, unlined gloves are constructed of latex and provide defense against tears, abrasions, cuts, and punctures.
| Temperature (English) Min | -40°F |
|---|---|
| Chlorinated | No |
| Grip Design | Smooth |
| Temperature (English) Max. | 194°F |
| Packaging Type | Carton |
| Temperature (Metric) Max | 90°C |
| Color | Black |
| Material | Butyl |
| For Use With (Application) | Handling Sensitive or Hazardous Materials in an Inert or Contained Atmosphere |
| Hand | Ambidextrous |
| Temperature (Metric) Min. | -40°C |
| Certifications/Compliance (Europe) | PPE Category III Directive 2016/425 EC Type |
| For Use With (Equipment) | Dry Box, Isolator, RABS |
| Product Type | Dry Box, Isolator Gloves |
| Latex Free | Yes |
| Manufacturing/QMS Audit Standards | ISO 9001:2015 |
| Temperature (English) Min | -4°F |
|---|---|
| Chlorinated | No |
| Grip Design | Smooth |
| Temperature (English) Max. | 248°F |
| Packaging Type | Carton |
| Temperature (Metric) Max | 120°C |
| Color | Natural White |
| Material | CSM |
| For Use With (Application) | Aseptic and Sterile Processes, Such as Pharmaceutical Manufacturing, Compounding, and Filling. |
| Hand | Ambidextrous |
| Temperature (Metric) Min. | -20°C |
| Certifications/Compliance (Europe) | PPE Category III Directive 2016/425 EC Type |
| For Use With (Equipment) | Dry Box, Isolator, RABS |
| Product Type | Dry Box, Isolator Gloves |
| Latex Free | Yes |
| Manufacturing/QMS Audit Standards | ISO 9001:2015 |
AL Glove Systems GSE Isolator Box Gloves
Resistant to disinfection chemicals, UV and ozone resistant, and fully electrically conductive.
| Temperature (English) Min | -4°F |
|---|---|
| Grip Design | Smooth |
| Temperature (English) Max. | 266°F |
| Packaging Type | Carton |
| Temperature (Metric) Max | 130°C |
| Color | Black |
| Material | EPDM |
| For Use With (Application) | Aseptic and Sterile Processes, Such as Pharmaceutical Manufacturing, Compounding, and Filling. |
| Hand | Ambidextrous |
| Temperature (Metric) Min. | -20°C |
| Certifications/Compliance (Europe) | PPE Category III Directive 2016/425 EC Type |
| For Use With (Equipment) | Dry Box, Isolator, RABS |
| Product Type | Dry Box, Isolator Gloves |
| Latex Free | Yes |
| Certifications/Compliance | FDA (Food and Drug Administration) Vol. 21, Cap. 177.2600 |
| Manufacturing/QMS Audit Standards | ISO 9001:2015 |
AL Glove Systems GSE Duo Isolator Box Gloves
Dual-layer black/white gloves, resistant to disinfectants, UV/ozone, and fully electrically conductive, compliant with EU GMP Annex 1.
| Temperature (English) Min | -4°F |
|---|---|
| Chlorinated | No |
| Grip Design | Smooth |
| Temperature (English) Max. | 266°F |
| Length (Metric) | 800 mm |
| Packaging Type | Carton |
| Temperature (Metric) Max | 130°C |
| Color | Multi |
| Length (English) | 32 in. |
| Material | EPDM |
| For Use With (Application) | Aseptic and Sterile Processes, Such as Pharmaceutical Manufacturing, Compounding, and Filling. |
| Hand | Ambidextrous |
| Temperature (Metric) Min. | -20°C |
| Thickness (Metric) | 0.4 mm |
| Certifications/Compliance (Europe) | PPE Category III Directive 2016/425 EC Type |
| For Use With (Equipment) | Dry Box, Isolator, RABS |
| Product Type | Dry Box, Isolator Gloves |
| Thickness (English) | 16 mil |
| Latex Free | Yes |
| Certifications/Compliance | FDA (Food and Drug Administration) Vol. 21, Cap. 177.2600 |
| Manufacturing/QMS Audit Standards | ISO 9001:2015 |
Ansell™ BioClean™ Nitrile RABS/Isolator Sleeve/Glove System
The BioClean™ Nitrile RABS/Isolator Sleeve/Glove System is a clean and sterile sleeve/glove system. The Nitrile sleeve attaches to a size 8.5 hand specific PCP glove (BioClean™ BPZS) by a channel ring and o'ring.