Filtered Search Results
Cytiva Disposable PD-10 Desalting Columns
Use for desalting and buffer exchange, as well as removal of low-molecular weight compounds. Cytiva Life Sciences™ Disposable PD-10 Desalting Columns provide fast, high-recovery.
Cytiva HyClone HyPure Water for Injection (WFI) Quality Water
Support cell culture growth and biomanufacturing processes with Water for Injection (WFI) quality water.
| Physical Form | Liquid |
|---|---|
| Recommended Storage | 2°C to 30°C |
| Shelf Life | 24 Months |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Thickness (Metric) | 260 μm |
|---|---|
| Flow Rate | 10.5 sec./100 mL |
| Particle Retention | 1.2 μm |
| Temperature (English) Max. | 932°F |
| Basis Weight | 53 g/m2 |
| Shape | Circle |
| Format | Disc |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Thickness (English) | 0.01 in. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Waterflow Rate | 105 mL/min |
Cytiva Whatman™ Qualitative Filter Paper: Grade 1 Circles
Covers a wide range of laboratory applications and is frequently used for clarifying liquids. Whatman™ Qualitative Filter Paper: Grade 1 Circles are widely used standard grade filter papers for routine applications with medium retention and flow rates.
| Thickness (Metric) | 180 μm |
|---|---|
| Flow Rate | 57mL/min. (water) |
| Particle Retention | >11 μm |
| Basis Weight | 87 g/m2 |
| Format | Disc |
| Airflow Rate | 13sec./100mL/sq. in. |
| Grade | Grade 1 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 150 sec. |
| For Use With (Application) | A widely used standard grade filter paper for routine applications with medium retention and flow rate. It covers a wide range of laboratory applications and is frequently used for clarifying liquids. |
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva Ficoll-Paque™ PLUS Media
Recognized standard in laboratories worldwide for isolation of human lymphocytes from peripheral blood. Cytiva™ Ficoll-Paque™ PLUS Media maintains the viability and a representative distribution of B and T lymphocytes.
| Content And Storage | 4–30°C |
|---|---|
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| Endotoxin Level | < 0.12 EU/mL |
| Shelf Life | 3 years |
| For Use With (Application) | Cell Isolation |
| Sterility | Sterile |
| Density | 1.078 g/mL |
Cytiva HyClone™ Penicillin Streptomycin 100X Solution
Used to control/destroy destructive microorganisms such as bacteria
Cytiva Fetal Bovine Serum, Heat Inactivated
GE Hyclone Fetal Bovine Serum, Heat Inactivated, is sourced from South America and complies with the EU regulations.
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Cytiva Whatman™ 1PS Disposable Phase Separating Paper
Creates a hydrophobic filter that can replace separatory funnel in some applications. Whatman™ 1PS Disposable Phase Separating Paper is impregnated with stable silicone to allow solvent phases to pass through while retaining aqueous phases.
| Type | Separator Paper |
|---|---|
| Material | Fiberglass/Silicone |
| For Use With (Application) | Liquid phase separation |
Cytiva Whatman™ Type WCN Cellulose Nitrate Membranes
Recommended for majority of routine applications, this membrane is manufactured under strictly controlled conditions. Whatman™ Type WCN Cellulose Nitrate Membranes narrow pore size distribution for improved surface capture and analysis.
| Color | White |
|---|---|
| Material | Cellulose Nitrate |
| Autoclavable | Autoclavable |
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |