missing translation for 'onlineSavingsMsg'
Få mere at vide

Thermo Scientific™ TR-FRET Coregulator Buffer G

Artikelnummer. 10184833
Skift visning
Klik for at se tilgængelige muligheder
Quantity:
25mL, 25 mL
Pakningsstørrelse:
Each
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Quantity unitSize
10184833 25mL, 25 mL Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Denne vare kan ikke returneres. Se returpolicy
For Research Use Only. All usage must comply with product instructions.
 
Artikelnummer. 10184833 Leverandør Thermo Scientific™ Leverandørnr. PV4553

Please to purchase this item. Need a web account? Register with us today!

Denne vare kan ikke returneres. Se returpolicy
For Research Use Only. All usage must comply with product instructions.
 

A specialized nuclear receptor buffer that can be used with Invitrogen's collection of purified nuclear receptor proteins and assays.

A specialized nuclear receptor buffer that can be used with Invitrogen's collection of purified nuclear receptor proteins and assays.

TRUSTED_SUSTAINABILITY

Tekniske data

Description TR-FRET Coregulator Buffer G, 25mL, Liquid, Store at 4°C, Proprietary Buffer, Water Soluble, Used For Pharma & Biopharma, Target & Lead Identification & Validation
Format Liquid
Quantity 25mL, 25 mL
For Use With (Equipment) LanthaScreen™ Nuclear Receptor Cofactor Interaction Assays
Content And Storage TR-FRET Coregulator Buffer G may be shipped frozen or at room temperature. Store at 4°C.
Shipping Condition Approved for shipment at Room Temperature or on Wet or Dry Ice
I have no assay window in my TR-FRET assay. What is the reason?

The single most common reason that a TR-FRET assay fails is that an incorrect choice of emission filters was made. Unlike other fluorescent assays, the filters used in a TR-FRET assay must be exactly those that are recommended for your instrument as the emission filter choice can make or break the assay. The excitation filter has more of an impact on the assay window. Please refer to our instrument setup guides in our instrument compatibility portal (https://www.thermofisher.com/instrumentsetup). If your instrument is not listed there, please contact Drug Discovery Technical Support at drugdiscoverytech@thermofisher.com.

Note: Test your microplate reader's TR-FRET setup before you begin any work with your assay. Using reagents that you have already purchased for your assay, you can test the microplate reader's TR-FRET setup. Please refer to the Terbium (Tb) Assay (http://tools.thermofisher.com/content/sfs/manuals/LanthaScreen_Tb_Instrument_Control_Application_Note17Sep10.pdf) and Europium (Eu) Assay (http://tools.thermofisher.com/content/sfs/manuals/Eu_Instrument_Control_AppNote_12Nov10.pdf) Application Notes for plate reader setup.

For Research Use Only. Not for use in diagnostic procedures.

Produkttitel
Vælg et problem

Ved at klikke på Send, anerkender du, at du kan blive kontaktet af Fisher Scientific med hensyn til den feedback, du har givet i denne formular. Vi deler ikke dine oplysninger til andre formål. Alle angivne kontaktoplysninger skal også vedligeholdes i overensstemmelse med vores Privatlivspolitik.