missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Slide-A-Lyzer™ 3.5K MWCO Dialysis Cassettes

Remove buffer salts and contaminants and maximize sample recovery using this semi-permeable membrane with a 3500-dalton protein MW cut-off (MWCO).

Brand:  Thermo Scientific™ 66107

UNSPSC : 41123101

Code : PN

Additional Details : Weight : 0.10000kg

 View more versions of this product

Product Code. 10416144

  • £138.00 / Each


EU Stock 20
Add to basket

Specifications

Description

Available in four different cassette sizes to accommodate sample volumes between 0.5 and 30mL, these devices are easier to use than traditional dialysis tubing, providing both faster buffer exchange and more complete sample recovery. Slide-A-Lyzer Cassettes can be used for a wide range of applications including low molecular-weight contaminant removal, buffer exchange, desalting, equilibrium dialysis, and sample concentration.

The cassettes are constructed from two sheets of low-binding, regenerated-cellulose dialysis membrane that are hermetically sealed on either side of a silicone-like gasket inside an inert plastic frame. The membrane and cassette materials are compatible with most common laboratory chemicals and buffers. Liquid samples are easily added and removed by penetrating the self-sealing gasket with a hypodermic needle attached to a syringe. No knots, clips or caps are needed to seal the units and prevent leaking and sample-loss during the dialysis procedure.

Highlights:

  • Easy to use – no knots or clamps are needed; just inject sample into cassette and begin dialysis

  • Fast dialysis – flat cassette chamber with two membranes provides high surface-area to volume ratio that maximizes diffusion rate compared to cylindrical dialysis tubing

  • High recovery – rectangular cassette design maximizes recovery of entire sample volume via any one of the four corner injection ports

  • Four cassette sizes – select the cassette that best suits your sample volume

  • Color-coded – pink cassette frame specifies cassettes with the 3500 MW pore size membrane

3.5K Dialysis Membrane Specifications:

  • Composition: Regenerated cellulose synthesized by the Viscose method
  • Thickness: 0.9 to 1.2mil (22.5 to 30μm)
  • Hydration Required Before Use: 30 seconds
  • Glycerol Content: Trace
  • Sulfur Content: 0.1 to 0.15%
  • Heavy Metals Content: Trace

Item-Specific Features:

    30mL cassette has built-in air chamber for flotation

Includes:

Kits contain cassettes plus an equal number of syringes with 18-gauge needles and single-cassette float buoys

Description & Specifications

Specifications

Slide-A-Lyzer Dialysis Cassette Kit, 3.5K MWCO, 12mL
8 cassette kit
Dialysis Cassettes, 8 cassettes
12mL
Multi-component kit with cassettes, syringes and float buoys
8 samples, each 3 to 12mL
3500 Da
Special Offers

Special Offers

  • Thermo Scientific Pierce
    Slide-A-Lyzer™ Dialysis Cassettes help facilitate the rapid and effective dialysis of sample volumes ranging from 100 μL to 30 mL.