missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Immuno Clear Standard Modules
BIOPHARMA

Product Code. 10032391
Change view
Click to view available options
Surface Treatment:
Enhanced Binding
Hydrophilic
Immulon 1 B
Immulon 2 HB
Immulon 4 HBX
MaxiSorp
MediSorp
MultiSorp
PolySorp
Volume (Metric) Working:
250 μL
330 μL
350 μL
Well Shape:
Curved Edges, Flat Bottom (C-well)
Round
Round, C Bottom
Round, Flat Bottom (F-well)
Well Design:
C12
C8
F12
F16 (2x8 wells)
F8
U16
U8
Unit Size:
Pack of 100
Pack of 120
Pack of 320
Pack of 50
Pack of 60
Pack of 640
25 product options available for selection
Product selection table with 25 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Surface Treatment Volume (Metric) Working Well Shape Well Design unitSize
10032391 MediSorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 60
10721634 MaxiSorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 120
10294021 PolySorp 250 μL Curved Edges, Flat Bottom (C-well) C8 Pack of 60
10574941 MaxiSorp 250 μL Round, C Bottom C8 Pack of 60
10274071 PolySorp 250 μL Round, C Bottom C8 Pack of 60
10172881 MaxiSorp 250 μL Round, C Bottom C8 Pack of 60
10052411 MultiSorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 60
10797921 MaxiSorp 350 μL Round, Flat Bottom (F-well) F16 (2x8 wells) Pack of 60
10554831 MaxiSorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 60
10673832 PolySorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 60
12799995 Hydrophilic 250 μL Round U16 Pack of 320
10174811 MaxiSorp 350 μL Round, Flat Bottom (F-well) F16 (2x8 wells) Pack of 320
10738091 PolySorp 350 μL Round, Flat Bottom (F-well) F16 (2x8 wells) Pack of 320
10227541 MaxiSorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 640
10748091 PolySorp 350 μL Round, Flat Bottom (F-well) F8 Pack of 640
10244551 MaxiSorp 250 μL Round, C Bottom C12 Pack of 60
10505411 PolySorp 250 μL Round, C Bottom C12 Pack of 60
10386231 MaxiSorp 250 μL Round U8 Pack of 60
10396231 PolySorp 250 μL Round U8 Pack of 60
10079074 Immulon 2 HB 330 μL Round, Flat Bottom (F-well) F12 Pack of 320
10406165 Immulon 2 HB 330 μL Round, Flat Bottom (F-well) F12 Pack of 100
10364025 Immulon 1 B 330 μL Round, Flat Bottom (F-well) F12 Pack of 100
10753886 Immulon 4 HBX 330 μL Round, Flat Bottom (F-well) F12 Pack of 100
10695757 Enhanced Binding 350 μL Round, Flat Bottom (F-well) F8 Pack of 50
10497305 Immulon 1 B 330 μL Round, Flat Bottom (F-well) F12 Pack of 320
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 25 options available.
25 options
This item is not returnable. View return policy
Product Code. 10032391 Supplier Thermo Scientific™ Supplier No. 467120
Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

Perform applications that deliver well-to-well reproducibility with these immuno clear standard modules. Manufactured to fit standard equipment.

Perform applications which are delivering well-to-well reproducibility with Thermo Scientific™ Immuno Clear Standard Modules, which feature Nunc™, Immulon™ and Microtiter™ module plates developed for ELISA techniques. Manufactured to fit standard equipment, modules provide flexible use of components with small sample sizes. They are backed by industry-leading quality standards and certifications.

Thermo Scientific standard modules are strip plates with solid modules that can be easily inserted and removed from their frame. This enhances the use of the plate with smaller sample sizes.

  • Several strip formats: 8-well strip, 12-well strip, 16-well strip (two columns of 8 wells)
  • Several well shapes: flat-bottom, C-bottom (radius edge), U-shape wells, StarWells (wells have fins to increase the surface area and enhance performance)
  • Several surfaces to maximize assay performance
  • Modules remain in frame when inverted
  • Stackable frame marked for lid orientation
  • Polystyrene wells in polyethylene frame
  • Ext. Dim.: 128 × 86mm

Choice of Surface

  • PolySorp™, Immulon 1B, and Universal Binding (UB) for adsorption of hydrophobic molecules
  • Medisorp™ and Immulon 2HB are slightly hydrophilic and bind a diverse range of biomolecules
  • MaxiSorp™, Immulon 4 HBX, and Enhanced Binding(EB) are hydrophilic and ideal for antibody sandwich assays
  • MultiSorp™ are very hydrophilic and works well for glycans and water soluble proteins

Ordering Information:

Free-standing modules. Cat. No. 95029440 and 464394 are certified. Frames and modules available separately. Sealing tape and strip caps are available. Color-coded modules are available on request. Contact your Customer Service or Sales Representative for further details.

Certifications

Products specified in chart are certified for: Adsorption of IgG; CV of <5% between wells; all results +/-10% from mean; and background of all wells +/-0.005 absorbance units from mean.

TRUSTED_SUSTAINABILITY

Specifications

Breakapart No
Binding Property Slightly Hydrophilic
Certifications/Compliance Certified for adsorption of IgG; CV of <5% between wells
Certified Yes
Format Strip Plate
Lid With Lid
Detection Method Colorimetric
Packaging Inner packs of 10
Binding Type Adsorption
Color Clear
Product Type Frame
Material Polystyrene
Volume (Metric) Well 400 μL
No. of Wells 96
Volume (Metric) Working 350 μL
Sterility Non-sterile
Surface Treatment MediSorp
Well Shape Round, Flat Bottom (F-well)
No. per Case 60
No. per Pack 10
Plate Blocking None
Quantity 60/Cs.
Target Molecule Proteins
Well Design F8
Show More Show Less
What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

Which Nunc immunodiagnostic passive surface should I choose: PolySorp, MediSorp, MaxiSorp, or MultiSorp?

Our passive immunodiagnostic surfaces are based on a series of treatments that modify the polystyrene surface to different final levels of hydrophilicity. Selection of one of these surfaces for ELISA development should be based on the characteristics of the biomolecule you seek to immobilize. PolySorp is fairly hydrophobic and should be used for biomolecules that have hydrophobic domains, e.g., lipids, lipoproteins, and large proteins. MediSorp is slightly hydrophilic and can be used for biomolecules with hydrophilic and hydrophobic properties, e.g., medium-to-large proteins such as albumin, or amphiphilic biomolecules such as LPS. MaxiSorp is quite hydrophilic, optimized for binding of IgG (and any other molecule with similar characteristics) and thus is a popular choice for sandwich ELISA and similar protocols. MultiSorp is very hydrophilic, and in turn will immobilize very hydrophilic biomolecules such as glycoproteins. Some optimization will always be necessary, and in many cases screening for binding optimization may involve a few surface types.

What is the difference between a certified and an uncertified immunodiagnostic plate, e.g., Cat. No. 439454 vs. 442404?

There is no difference in the manufacturing process. Certified plates are performance tested (using an antibody binding protocol) during quality control, whereas uncertified plates are not. This test is expensive for us to perform, so we offer the uncertified version at cost savings customers for whom antibody binding testing results are not critical.

Product Title
Select an issue

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.