Learn More
- Home
- Products
- Chromatography Columns and Cartridges
- HPLC Columns and Cartridges
- HPLC Columns
- Thermo Scientific™ Hypersil GOLD™ Phenyl HPLC Columns
Thermo Scientific™ Hypersil GOLD™ Phenyl HPLC Columns
Product Code. 10207834 Shop All Thermo Scientific Products| Code produit. | Length (Metric) | Diameter (Metric) | Particle Size | Column Format | unitSize |
|---|---|---|---|---|---|
| 10207834 | 100 mm | 2.1 mm | 1.9 μm | Analytical Column | Each |
| 16398576 | 250 mm | 10 mm | 5 μm | Preparative Column, Standard | Each |
| 10675335 | 50 mm | 2.1 mm | 5 μm | Analytical Column | Each |
| 10762907 | 50 mm | 4.6 mm | 5 μm | Analytical Column | Each |
| 10753477 | 100 mm | 2.1 mm | 5 μm | Analytical Column | Each |
| 10127604 | 100 mm | 3 mm | 5 μm | Analytical Column | Each |
| 10753667 | 100 mm | 4.6 mm | 5 μm | Analytical Column | Each |
| 10014574 | 150 mm | 4.6 mm | 5 μm | Analytical Column | Each |
| 10005784 | 250 mm | 4 mm | 5 μm | Analytical Column | Each |
| 10442595 | 250 mm | 4.6 mm | 5 μm | Analytical Column | Each |
| 10351445 | 10 mm | 4 mm | 5 μm | Guard Cartridge, 4 Pk. | Pack of 4 |
| 10525435 | 10 mm | 3 mm | 5 μm | Guard Cartridge, 4 Pk. | Pack of 4 |
| 10025644 | 10 mm | 2.1 mm | 5 μm | Guard Cartridge, 4 Pk. | Pack of 4 |
| 10287924 | 150 mm | 4.6 mm | 3 μm | Analytical Column | Each |
| 10446984 | 150 mm | 3 mm | 3 μm | Analytical Column | Each |
| 10277924 | 150 mm | 2.1 mm | 3 μm | Analytical Column | Each |
| 10794627 | 150 mm | 1 mm | 3 μm | Analytical Column | Each |
| 10690256 | 100 mm | 4.6 mm | 3 μm | Analytical Column | Each |
| 10437324 | 100 mm | 3 mm | 3 μm | Analytical Column | Each |
| 10056364 | 100 mm | 2.1 mm | 3 μm | Analytical Column | Each |
| 10208264 | 50 mm | 2.1 mm | 3 μm | Analytical Column | Each |
| 10026124 | 10 mm | 4 mm | 3 μm | Guard Cartridge, 4 Pk. | Pack of 4 |
| 10279654 | 10 mm | 3 mm | 3 μm | Guard Cartridge, 4 Pk. | Pack of 4 |
| 10380915 | 10 mm | 2.1 mm | 3 μm | Guard Cartridge, 4 Pk. | Pack of 4 |
| 10595125 | 200 mm | 2.1 mm | 1.9 μm | Analytical Column | Each |
| 10431825 | 150 mm | 2.1 mm | 1.9 μm | Analytical Column | Each |
| 10422015 | 50 mm | 2.1 mm | 1.9 μm | Analytical Column | Each |
Description
Use for quick analysis of aromatic analytes, including glucocorticosteroids, estrogens, fat-soluble vitamins, and phospholipids.
Get excellent retention and unique selectivity for aromatic and moderately polar analytes with Thermo Scientific™ Hypersil GOLD™ Phenyl reversed phase HPLC columns. A butyl (C4) linker in the phenyl bonded phase allows for superior alignment of the phenyl ring with aromatic molecules, thus enhancing pi-pi interactions and improving the retention of the molecules. The C4 linker also provides the stationary phase with moderate hydrophobicity, making it ideal for the separation of analyte mixtures with varying polarity and aromaticity. The outstanding peak shape results in greater sensitivity.
- Provides selectivity complementary to that provided by alkyl chain phases
- Moderate hydrophobicity compared to C18
Meet the challenges of modern chromatography with state-of-the-art columns that provide outstanding performance and consistent separations. Twelve different chemistries are available so you can optimize separations and maximize productivity. Get outstanding peak shapes in reversed phase, ion exchange, HILIC, or normal phase chromatography.
- Excellent peak symmetry
- Narrow peaks for outstanding efficiency
- Enhanced sensitivity and improved resolution
- Exceptional reproducibility for reliable chromatography, column after column
- Solutions for high-throughput screening
- 1.9, 3, and 5μm particle sizes for all your separation needs
Spécification
Spécification
| Column Format | Analytical Column |
| Diameter (Metric) | 2.1 mm |
| For Use With | HPLC |
| Length (Metric) | 100 mm |
| Max. Pressure | 18130 psi (1250 bar) |
| Particle Size | 1.9 μm |
| pH | 2 to 8 |
| Pore Size | 175 Å |
| Surface Area | 220 m²/g |
| Temperature | 60°C |
| USP Type | L11 |
| Stationary Phase | Phenyl (Ph) |
| Product Line | Hypersil GOLD |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Carbon Load | 9% |
| Column Type | Reversed Phase |
| Endcapped | Yes |
| Phase | Reversed Phase |
| Afficher plus Afficher moins |
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.
En cliquant sur Soumettre, vous reconnaissez que vous pouvez être contacté par Fisher Scientific au sujet des informations que vous avez fournies dans ce formulaire. Nous ne partagerons pas vos informations à d'autres fins. Toutes les informations de contact fournies seront également conservées conformément à notre politique de confidentialité. Politique de confidentialité.