Filtered Search Results
Search results for "BDS C8"
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Column
For a high-quality, base-deactivated, fully endcapped phase with similar selectivity to C18 but slightly less retention, use Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns.
Pore Size | 130 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 7% |
Stationary Phase | C8 |
Phase | Reversed Phase |
Column Type | Reversed Phase |
Diameter (Metric) | 4.6 mm |
Surface Area | 170 m²/g |
USP Type | L7 |
Column Format | Analytical Column |
Thermo Scientific™ Hypersil™ PREP BDS C8 HPLC Columns
Scale up to prep LC using Hypersil PREP C8 BDS HPLC columns which offers selectivity similar to C18 but with reduced retention in analytical and preparative scale.
Pore Size | 145 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 185 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil™ BDS C8 Column, 3μm
For a high-quality, base-deactivated, fully endcapped phase with similar selectivity to C18 but slightly less retention, use Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns.
Pore Size | 130 Å |
---|---|
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
Column Format | Analytical Column |
Particle Size | 3 μm |
Carbon Load | 7% |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
pH | 2 to 8 |
USP Type | L7 |
Thermo Scientific™ Hypersil™ BDS Cyano HPLC Columns
For reliable, general purpose cyano columns, choose the base-deactivated silica Thermo Scientific™ Hypersil™ BDS Cyano LC Columns.
Pore Size | 130 Å |
---|---|
Carbon Load | 4% |
Stationary Phase | Cyano (CN) |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Mixed Mode |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
USP Type | L10 |
BD Mouse TNF Enhanced Sensitivity Flex Set (Bead C8)
For measuring soluble analytes present in very low concentrations
BD Cytometric Bead Array (CBA) Rat TNF; Flex Set, Bead C8
For detecting rat tumor necrosis factor in serum and cell culture samples
BD Cytometric Bead Array (CBA) Mouse TNF; Flex Set, Bead C8
For detection of mouse tumor necrosis factor in serum and cell culture supernatant samples
BD Cytometric Bead Array (CBA) Human G-CSF; Flex Set, Bead C8
For detecting human Granulocyte-Colony Stimulating Factor in serum, plasma, and cell culture samples
Antigen | CD59 |
---|---|
Regulatory Status | RUO |
Content And Storage | Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. |
Purification Method | Affinity Purified |
Target Species | Human |
Host Species | Mouse |
Conjugate | FITC |
Applications | Flow Cytometry |
Formulation | Aqueous buffered solution containing BSA and ≤0.09% sodium azide. |
Immunogen | Human Erythrocytes |
Classification | Monoclonal |
Isotype | IgG2a κ |
Primary or Secondary | Primary |
Antigen | CD59 |
---|---|
Regulatory Status | RUO |
Content And Storage | Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. |
Purification Method | Affinity Purified |
Target Species | Human |
Host Species | Mouse |
Conjugate | PE |
Applications | Flow Cytometry |
Formulation | Aqueous buffered solution containing BSA and ≤0.09% sodium azide. |
Immunogen | Human Erythrocytes |
Classification | Monoclonal |
Isotype | IgG2a κ |
Primary or Secondary | Primary |