Dialysis and Desalting
Filtered Search Results
Thermo Scientific™ Zeba™ Spin Desalting Columns and Plates, 40K MWCO, 75 μL–10 mL
The new and enhanced Zeba Spin and Micro Spin Desalting columns and plates are designed for efficient desalting and buffer exchanging proteins with a molecular weight >40 kDa and removing small molecules less than 2 kDa. They provide exceptional desalting and protein recovery performance.
| Disposable | Single-use |
|---|---|
| MWCO | 40 kDa |
| Column Type | Size-exclusion, Proprietary Resin |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Zeba™ |
Thermo Scientific™ Zeba™ Dye and Biotin Removal Spin Columns and Filter Plates, 0.5–10 mL
Enable fast and efficient removal of non-reacted fluorescent dyes, biotin, reducing agents, and crosslinkers from protein samples with Thermo Scientific Pierce Zeba Dye and Biotin Removal columns and filter plates.
| Shipping Condition | Room Temperature |
|---|---|
| Column Type | Proprietary Resin |
| Product Line | Zeba™ |
Cytiva HiTrap™ Desalting Prepacked Columns
For rapid convenient desalting and buffer exchange. HiTrap™ Desalting Prepacked Columns are prepacked, ready to use column for group separation between high and low molecular weight substances.
| Disposable | Reusable |
|---|---|
| Particle Size | >20 μm (dry), 15 to 88 μm (wet) |
| Content And Storage | 4°C to 30°C in 20% Ethanol |
| Diameter (English) Inner Column | 0.62 in. |
| Description | HiTrap Desalting are ready-to-use 5 mL columns prepacked with Sephadex G-25 Superfine resin for fast and convenient desalting and buffer exchange. |
| Volume (Metric) Bed | 5 mL |
| For Use With (Application) | For rapid convenient desalting and buffer exchange |
| Diameter (Metric) Inner Column | 16 mm |
Cytiva HiPrep™ 26/10 Desalting Columns
Provide reliable and reproducible desalting and buffer exchange with sample sizes of up to 15mL per column. Cytiva HiPrep 26/10 Desalting Column is a convenient, easy-to-use column prepacked 53mL column with Sephadex G-25 Fine for desalting and buffer exchange.
| Disposable | Reusable |
|---|---|
| Particle Size | >20 μm (dry), 17 to 132 μm (wet) |
| Content And Storage | 4°C to 30°C in 20% Ethanol |
| Diameter (English) Inner Column | 1.02 in. |
| Description | HiPrep 26/10 Desalting are convenient, easy-to-use, 53 mL columns prepacked with Sephadex G-25 Fine resin for desalting and buffer exchange. |
| Volume (Metric) Bed | 53 mL |
| For Use With (Equipment) | Laboratory pump or chromatography system such as AKTA design |
| Product Type | HiPrep 26/10 Desalting |
| Diameter (Metric) Inner Column | 26 mm |
Thermo Scientific™ Zeba™ Spin Desalting Columns, Plates, and Cartridges, 7K MWCO, 0.5–100 mL
Perform high-throughput protein recovery (7K MWCO) and sample desalting for mass spectrometry, HPLC, capillary electrophoresis, metabolite screening, and assay development with ready-to-use Thermo Scientific Pierce Zeba desalting chromatography columns, plates, and cartridges.
| MWCO | 7.0 kDa |
|---|---|
| Column Type | Size-exclusion, Proprietary Resin |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Zeba™ |
Thermo Scientific™ Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL
Separate proteins and other macromolecules from low-molecular weight buffer salts and reagents with Thermo Scientific Pierce 7K MWCO (molecular-weight cutoff) Polyacrylamide Spin Desalting Columns, which are porous polyacrylamide-based gel-filtration columns for biological sample preparation.
| MWCO | 7.0 kDa |
|---|---|
| Content And Storage | Upon receipt store at 4°C. |
| Format | Spin Column |
| Description | Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL |
| Product Type | Spin Desalting Column |
| Column Type | Size-exclusion, Polyacrylamide Resin |
| Purification Target | Buffer Exchange, Protein |
| Sample Volume (Metric) | 30 to 120 μL |
| Product Line | Pierce™ |
Thermo Scientific™ Pierce™ Dextran Desalting Columns (5K MWCO)
Ready-to-use, gel-filtration Thermo Scientific Pierce Dextran Desalting Columns can separate proteins and macromolecules from low-molecular weight buffer salts and reagents up to 5000 Daltons (5 kDa) in 5- or 10-mL volumes.
| Disposable | Single-use |
|---|---|
| MWCO | 5.0 kDa |
| Content And Storage | Store at room temperature or 4°C. |
| Format | Gravity Flow Column |
| Product Type | Desalting Column |
| Column Type | Size-exclusion, Dextran Resin |
| Quantity | 5 Columns |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Pierce™ |
Thermo Scientific™ Pierce™ Polyacrylamide Desalting Columns, 1.8K MWCO, 5 mL
Thermo Scientific Pierce 1.8K MWCO (molecular-weight cutoff) Polyacrylamide Desalting Columns are ready-to-use, disposable, gel-filtration columns for separating proteins and other macromolecules from low-molecular-weight buffer salts and reagents.
Cytiva HiTrap™ Macrocap™ SP
For use in method scouting, group separations, sample concentration and sample clean-up of charged biomolecules. Cytiva Lifescience HiTrap™ Macrocap™ SP are made of biocompatible polypropylene that does not interact with biomolecules.
Cytiva HiPrep™ SP HP 16/10 Column
Provide fast, preparative separations of proteins and other biomolecules
Thermo Scientific™ POROS™ GoPure™ Ethyl Pre-packed Column, 0.5 x 5 cm, 1 mL
Thermo Scientific™ POROS™ GoPure™ 0.5 cm pre-packed columns are intended for the screening of POROS ion exchange and hydrophobic interaction chromatography (HIC) resins or for small-scale purification.
Cytiva HiTrap™ Capto™ SP ImpRes IEX Columns
High-throughput medium for intermediate and polishing protein purification
| Content And Storage | 4°C to 30°C, 0.2M Sodium Acetate in 20% Ethanol |
|---|---|
| For Use With (Application) | HiTrap Capto SP ImpRes chromatography column is packed with a strong cation exchange modern resin for high resolution, small-scale protein purification. |
| Diameter (Metric) Inner Column | 7 mm |
| Particle Size | 90 μm (d50V) |
|---|---|
| Ligand Type | Quaternary amine |
| Content And Storage | 4°C to 30°C in 20% Ethanol |
| Matrix | Highly cross-linked agarose with dextran surface extender |
| Description | HiTrap Capto Q |
| pH | 2 to 12 |
| Column Material | Polypropylene |
| For Use With (Application) | HiTrap Capto Q chromatography column is prepacked with a strong anion exchange modern resin for small scale protein purification. |
| Particle Size | 90 μm (d50V) |
|---|---|
| Ligand Type | Sulfonate group |
| Content And Storage | 4°C to 30°C, 0.2M Sodium Acetate in 20% Ethanol |
| Matrix | Highly cross-linked agarose with dextran surface extender |
| pH | 4 to 12 |
| Column Material | Polypropylene |
| For Use With (Application) | HiTrap Capto S chromatography column is prepacked with a strong cation exchange modern resin for small scale protein purification. |
Cytiva HiTrap™ Capto™ Q ImpRes IEX Columns
High-throughput medium for intermediate and polishing protein purification
| Content And Storage | 4°C to 30°C in 20% Ethanol |
|---|---|
| For Use With (Application) | HiTrap Capto Q ImpRes chromatography column is packed with a strong anion exchange modern resin for high resolution, small-scale protein purification. |
| Diameter (Metric) Inner Column | 7 mm |