pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Resolution (pH) | 0.01 |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Range (pH) | -1.00 to 15.00 |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Accuracy (pH) | ±0.02 |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Calibration Points (pH) | 1 to 3 |
| Calibration Modes | pH, conductivity, TDS, salinity, temperature |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Cup-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS cup-sensor pocket testers for a variety of applications including agriculture, aquariums and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Fisherbrand™ Replacement Probes for Traceable™ Conductivity and TDS Meters
For use with Traceable Conductivity and TDS Meters.
| Type | Conductivity Probe |
|---|---|
| Material | Glass |
Oakton™ EcoTestr™ CTS1 Pocket Conductivity, Salinity and TDS Meter
CTS1 Pocket Conductivity, Salinity and TDS Meter - Measuring water quality is easier and faster. The display is larger with a better viewing angle, has indicators for battery life, readiness and calibration, and shows both the parameter and temperature readings simultaneously. The CTS Testr takes three auto point for EC calibration.
Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Oakton™ pH 700, CON 700, pH-CON 700 pH/Conductivity Benchtop Meters, Measures conductivity, TDS and temperature
An affordable way to take consistent, accurate conductivity measurements in your laboratory.
| Warranty | 3 Years |
|---|---|
| Temperature Compensation | Automatic or manual from 0° to 100°C |
| Display Type | LCD |
| Voltage | 120/240 V |
Thermo Scientific™ Accessories for Eutech™ 6+ Conductivity/TDS/Salinity Meters
Replacement electrodes and Grip-Clip™ electrode holder.
Fisherbrand™ accumet™ Replacement Conductivity/TDS/Temperature Probe - Mercury - Free
Replacement probe to be used for conductivity, TDS, and temp.
Hanna Instruments™ pH/Conductivity/TDS Tester
Designed for high accuracy measurements using one meter. Hannna Instruments™ pH/Conductivity/TDS Tester includes easy to read dual LCD display of pH/°C or TDS/°C. Includes 'HOLD' function and replaceable pH electrode.
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Pin-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS pin-sensor pocket testers for a variety of applications including hydroponics, pools, spas and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Hanna Instruments™ Waterproof pH/Conductivity/TDS Tester
Makes measuring pH quick and easy. Hanna Instruments™ Waterproof pH/Conductivity/TDS Tester is lightweight and waterproof offering high accuracy pH, EC/TDS and temperature measurements in a single handheld unit.
Thermo Scientific™ Carrying Kit Set for Eutech™ Cond 6+ and TDS 6+ meters
Eutech™ Carrying Kit Cases are thoughtfully designed to hold your Eutech™ meter and electrodes.
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Range (Resistivity) | 1.0Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (30 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Channels | 3 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | ±0.5% reading |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Resolution (Resistivity) | 0.1 Ωminimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Thermo Scientific™ Orion™ Star A Series Portable Meter Conductivity and DO Probe Holder
Use the Thermo Scientific™ Orion™ Star A Series Portable Meter Conductivity and DO Probes Holder with the Star A series portable meter armor to protect your sensors in the field
Eutech™ TDS 6+ handheld meters
Get quick and accurate total dissolved solids measurements in the field, laboratories, and schools.
| Battery Life | >500 hr. |
|---|---|
| Temperature Compensation | Automatic or Manual (0 to 80°C) |
| Accuracy (TDS) | ±% Full-scale ± LSD |
| Range (TDS) | 0.00 to 9.99 ppm, 10.0 to 99.9 ppm, 100 to 999 ppm, 1.00 to 9.99 ppt, 10.0 to 99.9 ppt |
| Measurement Modes | TDS with Temperature |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Resolution (TDS) | 0.05% Full-scale |
| Temperature Range (Metric) | 0.00°C to 100.0°C (80.0°C with Supplied Probe) |
| Battery Type | 4 x 1.5V AAA Alkaline (included) |
| Accuracy (Temperature) | ±0.5°C (±0.9°F) |
| TDS Factor Range | 0.30 to 1.00 |