SPE Disks and Cartridges
- (2)
- (3)
- (1)
- (3)
- (3)
- (3)
- (3)
- (3)
- (3)
- (1)
- (2)
- (2)
- (1)
- (1)
- (3)
- (3)
- (3)
- (2)
- (2)
- (1)
- (2)
- (2)
- (2)
- (2)
- (2)
- (11)
- (2)
- (3)
- (4)
- (1)
- (4)
- (4)
- (3)
- (1)
- (3)
- (3)
- (3)
- (3)
- (3)
- (3)
- (3)
- (7)
- (15)
- (12)
- (3)
- (1)
- (4)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (13)
- (2)
Filtered Search Results
Avantor™ BAKERBOND Speedisk™ Extraction Disks
Maximize capacity, adsorption and SPE speed. Avantor BAKERBOND Speedisk Extraction Disks are neither cartridge nor membrane that provides an excellent SPE tool for environmental samples and combines a thin bed of BAKERBOND sorbent with a special laminar configuration for testing drinking water, ground water, waste water, solid waste or process streams.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| For Use With (Equipment) | Expanded Extraction Station (8095-06) |
|---|---|
| Diameter (Metric) Outer | 50 mm |
| Quantity | 20/Pk. |
| Sorbent | C18 XF |
| Pore Size | 60 Å |
|---|---|
| Particle Size | 45 μm |
| Type | Chromafix C18 ec Cartridge |
| Carbon Load | 14% |
| Endcapped | Yes |
| Quantity | 50 Pack |
| Surface Area (Metric) | 500 m2/g |
| Sorbent | C18 ec |
| For Use With (Application) | Non-Polar Compounds, Aflatoxins, Amphetamines, Antibiotics, Antiepileptics, Barbiturates, Caffeine, Drugs, Preservatives, Fatty Acids, Nicotine, PAHs, Pesticides, PCBs, Heavy Metals, Vitamins, Very Well Suited for Desalting of Samples |
| Base Material | Silica |
| Pore Size | 60 Å |
|---|---|
| Particle Size | 45 μm |
| Type | Chromafix C18 Cartridge |
| Carbon Load | 14% |
| Quantity | 50 Pack |
| Surface Area (Metric) | 500 m2/g |
| Sorbent | C18 |
| For Use With (Application) | Non-Polar Compounds, Pesticides |
| Base Material | Silica |
| Pore Size | 50 to 60 Å |
|---|---|
| Particle Size | 45 or 85 μm |
| Type | Chromafix HR-XCW Cartridge |
| Quantity | 50 Pack |
| Surface Area (Metric) | 850 m2/g |
| Sorbent | Weak carboxylic acid modified polymeric cation exchanger |
| For Use With (Application) | Basic Compounds Like Quaternary Amines, Basic Active Ingredients From Strongly Matrix-Contaminated Samples |
| Base Material | Spherical PS/DVB Copolymer |
Avantor™ BAKERBOND Speedisk™ SAX Quaternary Amine Extraction Disk
Maximize capacity, adsorption and SPE speed. Avantor BAKERBOND Speedisk SAX Quaternary Amine Extraction Disk are neither cartridge nor membrane that provides an excellent SPE tool for environmental samples and combines a thin bed of BAKERBOND sorbent with a special laminar configuration for testing drinking water, ground water, waste water, solid waste or process streams.
| Pore Size | 60 Å |
|---|---|
| Particle Size | 45 μm |
| Type | Chromafix SA Cartridge |
| Quantity | 50 Pack |
| Surface Area (Metric) | 500 m2/g |
| Sorbent | SA |
| For Use With (Application) | Amino Acids, Amines, Chlorophyll, PCBs |
| Base Material | Silica |
| Pore Size | 55 to 65 Å |
|---|---|
| Particle Size | 45 or 85 μm |
| Type | Chromafix HR-XAW Cartridge |
| Quantity | 50 Pack |
| Surface Area (Metric) | 850 m2/g |
| Sorbent | Weakly basic secondary and tertiary ammonium polymeric anion exchanger |
| For Use With (Application) | Perfluorinated Surfactants, Acidic Compounds Like Sulfonates, Active Ingredients From Strongly Matrix-Contaminated Samples Like, e.g., Urine, Plasma, Serum |
| Base Material | Spherical PS/DVB Copolymer |
Macherey-Nagel™ Chromafix™ HR-P Cartridge
Resolve a number of components from water or oil. Chromafix™ HR-P Cartridges contain highly porous polystyrene-divinylbenzene adsorbent resin for SPE.
| Particle Size | 50 to 100 μm |
|---|---|
| Type | Chromafix HR-P Cartridge |
| Resin Composition | Polystyrene-divinylbenzene adsorbent resin |
| Quantity | 50 Pack |
| Surface Area (Metric) | 1200 m2/g |
| Sorbent | HR-P |
| For Use With (Application) | Aromatic Compounds, Phenols From Water, Nitroaromatics From Water, Pesticides From Water, PAHs From Oil |
| Type | Chromafix Dry (Na2 SO4) Cartridge |
|---|---|
| Quantity | 50 Pack |
| For Use With (Application) | Removal of Traces of Water From Organic Solutions |
| Base Material | Dry (Na2 SO4) |
Restek™ Resprep™-C18 and Resprep™-C8 SPE Disks
Extract analytes using high flow rates with significantly less clogging
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Type | SPE Disk |
|---|---|
| Diameter (Metric) Outer | 4.7 cm |
| Material | Glass Fiber |
| Certifications/Compliance | EPA 525.1, 506, 550.1, 549.1 |
Restek™ Bonded Reversed Phase Resprep SPE Cartridges
Hydrophobic (nonpolar) silica-based adsorbents; used to extract hydrophobic analytes from polar matrices.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Type | SPE Cartridge |
|---|---|
| Adsorbent Type | Hydrophobic (non-Polar) |
| Endcapped | Yes |
| Material | HDPE |
| Column Phase | Reversed Bonded |
| Sorbent | C18 (high load) |
| Base Material | Silica |
Avantor™ BAKERBOND Speedisk™ Oil and Grease Extraction Disk
Maximize capacity, adsorption and SPE speed. Avantor BAKERBOND Speedisk Oil and Grease Extraction Disk are neither cartridge nor membrane that provides an excellent SPE tool for environmental samples and combines a thin bed of BAKERBOND sorbent with a special laminar configuration for testing drinking water, ground water, waste water, solid waste or process streams.
| Pore Size | 60 Å |
|---|---|
| Particle Size | 45 μm |
| Type | Chromafix SiOH Cartridge |
| Quantity | 50 Pack |
| Surface Area (Metric) | 500 m2/g |
| Sorbent | SiOH |
| For Use With (Application) | Aflatoxins, Chloramphenicol, Pesticides, Steroids, Vitamins |
| Base Material | Weakly Acidic Silica |