Thermo Scientific™ Pierce™ Renilla-Firefly Luciferase Dual Assay Kit

Simultaneously detect intracellular Renilla and Red Firefly luciferase activity in mammalian whole cell lysates.

Brand: Thermo Scientific™

Manufacturer Part Number: 16185


UNSPSC: 41106500

Code: PN

Additional Details:
Additional Details: Weight: 0.01000kg

Product Code. 12201682

Quantity Price
1 £124.00 / Each
EU Stock 4
Add to basket

Description and Specification


Description Pierce Renilla-Firefly Luciferase Dual Assay Kit
Formulation Four-component kit
Kit Contents 100X Coelenterazine, 50uL
Quantity 100 rxn kit
Sufficient For 100 dual-luciferase assays in microplate wells

The Pierce Renilla-Firefly Luciferase Dual Assay Kit is a highly sensitive assay that allows for the simultaneous detection of Green Renilla and Red Firefly luciferase activity. Green Renilla luciferase acts as an experimental reporter with constitutively active red firefly as a normalization control. This reporter-and-control combination enables simultaneous monitoring of experimental reporter and control luciferase activities in a single-read assay without the need for two-step addition of substrate reagents or quenching. The assay working solution contains substrates for both luciferases, and the reactions occur simultaneously with flash-type kinetics. The resulting luminescent signals are spectrally resolvable using filters. In a single sample, researchers can assay transcriptional activity of regulatory elements, signal transduction pathways, and effects of activators or inhibitors.


  • Simultaneous – concurrent, filter-based, wavelength-separated detection of two luciferase activities

  • Sensitive – measure Green Renilla and red firefly luciferase activities in the same sample

  • Fast – no quenching step required, unlike in traditional sequential dual assays

  • Multiplex – capable of quantitating two cellular activities in the same sample(s)


Cell lysis buffer, reaction buffer, and substrates coelenterazine and D-luciferin


Green Renilla and Red Firefly luciferase reporters; Filter sets at 525nm±20nm for Green Renilla Luc and 615 to 675nm for Red Firefly Luc. Luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers; Injector required for assessing more than 24 wells at a time.

Recommended for:

Study two regulatory elements at the same time; Monitor two signaling pathways simultaneously; Enable studying more than one target per screen (e.g. off-target effects)