Filtered Search Results
Search results for "applied"
Applied Biosystems™ MicroAmp™ Optical 96-Well Reaction Plate
Designed to provide unmatched temperature accuracy and uniformity for fast, efficient PCR amplification
Skirt Style | Semi |
---|---|
No. of Wells | 96 |
For Use With (Equipment) | Thermal Cycler, Genetic Analyzer, DNA Analyzer |
Product Type | Microplate |
Volume (Metric) Working | 0.2 mL |
Barcode | No Barcode |
Color | Optical |
Material | Polypropylene |
Certifications/Compliance | Certified DNA/RNase Free |
Product Line | MicroAmp |
Applied Biosystems™ MicroAmp™ Fast Optical 96-Well Reaction Plate, 0.1 mL
Reduces PCR reaction time from 2 hours to as little as 25 minutes
SYBR™ Fast SYBR™ Green Master Mix
Designed for speed, SYBR™ Green Master Mix provides a fast, reliable, and cost-effective solution for RT-PCR application without compromising sensitivity, specificity, dynamic range, or PCR efficiency.
GC-Rich PCR Performance | High |
---|---|
Purity or Quality Grade | UP (Ultra Pure) |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Detection Method | SYBR |
Polymerase | AmpliTaq Fast DNA Polymerase, AmpliTaq Fast UP |
Product Type | Real Time PCR SYBR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7500 Fast System, 7900HT Fast System, StepOne™, Fast Mode, StepOnePlus™, Fast Mode |
Sample Type | DNA (Genomic), cDNA |
Reaction Speed | Fast |
Label or Dye | SYBR Green |
Product Line | SYBR™ |
Applied Biosystems™ High-Capacity cDNA Reverse Transcription Kit
The High Capacity cDNA Reverse Transcription Kit, available with or without RNase Inhibitor, contains all components necessary for the quantitative conversion of up to 2 μg of total RNA into single-stranded cDNA in a single 20 μL reaction.
Shipping Condition | Dry Ice |
---|---|
Format | Kit |
Reverse Transcriptase | MultiScribe |
Reaction Format | Separate components |
Final Product Type | First-Strand cDNA |
Reaction Speed | 120 min. |
Reagent Type | Reverse Transcription |
Ribonuclease H Activity | Yes |
Concentration | 50 U/μL |
Technique | Reverse Transcription |
Starting Material | RNA |
SYBR™ Power SYBR™ Green PCR Master Mix
Offers superior sensitivity and reproducibility, detecting as few as two copies of a target gene over a broad range of template concentrations.
GC-Rich PCR Performance | High |
---|---|
Purity or Quality Grade | LD (Low DNA) |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Detection Method | SYBR |
Polymerase | AmpliTaq Gold DNA Polymerase, AmpliTaq Gold LD |
Product Type | Real Time PCR SYBR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7300 System, 7500 System, 7700 System, 7900HT Fast System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
Sample Type | DNA (Genomic), cDNA |
Reaction Speed | Standard |
Label or Dye | SYBR Green |
Product Line | SYBR™ |
Applied Biosystems™ MagMAX™ Viral/Pathogen Nucleic Acid Isolation Kit
The MagMAX Viral/Pathogen Nucleic Acid Isolation Kit is designed to recover RNA and DNA from virus and gram-negative bacteria in samples such as blood, swabs, urine, and viral transport media (VTM).
Shipping Condition | Room Temperature |
---|---|
Format | 96 Deep-well Plate,24 Deep-well Plate |
Product Line | MagMAX™ |
Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
Shipping Condition | Wet Ice |
---|---|
Polymerase | Dual-Lock Taq DNA Polymerase |
Format | Tube |
Product Type | Real Time PCR SYBR Master Mix |
For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 7 Flex, StepOne™, StepOnePlus™, ViiA™ 7 System |
Sample Type | DNA |
Reaction Speed | Fast or Standard |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Product Line | PowerUP™, SYBR™ |
Detection Method | SYBR |
Applied Biosystems™ High-Capacity RNA-to-cDNA™ Kit
The High Capacity RNA-to-cDNA Kit is a streamlined reverse transcription kit designed for optimum performance with TaqMan Gene Expression Master Mix, Power SYBR Green PCR Master Mix, and other PCR enzymes.
Shipping Condition | Dry Ice |
---|---|
Format | Kit |
Reverse Transcriptase | MultiScribe |
Size (Final Product) | Up to 7 kb |
Reaction Format | Premixed Components |
Final Product Type | First-Strand cDNA |
Reaction Speed | 30 to 60 min. |
Reagent Type | Reverse Transcription |
Ribonuclease H Activity | Yes |
Optimal Reaction Temperature | 37°C |
Technique | Reverse Transcription |
Starting Material | RNA |
For Use With (Application) | Real Time PCR (qPCR),RT-PCR |
SYBR™ SYBR™ Select Master Mix
Cost-effective solution for real-time PCR applications.
GC-Rich PCR Performance | High |
---|---|
Content And Storage | The 2x mix contains SYBR™ GreenER™ dye, AmpliTaq™ DNA Polymerase UP, dNTPs with dUTP/dTTP blend, heat-labile UDG, ROX passive reference dye and optimized buffer components. Contains 1 X 1 mL tube, sufficient for 100, 20 μL reactions (10 μL Master Mix per reaction). Store at 2–8°C. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). See user guide for primer concentration recommendations for the StepOne and StepOnePlus systems. |
Purity or Quality Grade | UP (Ultra Pure) |
Form | Liquid |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Detection Method | SYBR |
Polymerase | AmpliTaq DNA Polymerase |
Format | Vial |
Product Type | Real Time PCR SYBR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
Sample Type | DNA (Genomic), cDNA |
Reaction Speed | Fast or Standard |
Label or Dye | SYBR GreenER |
Hot Start | Built-In Hot Start |
Sufficient For | 100 Reactions of 20 μL |
Product Line | SYBR™ |
Thermo Scientific™ Applied Biosystems™ SimpliAmp™ Strip Plate Tray Cover
Ease of sample setup and reduced handling steps enabled using the SimpliAmp Strip Plate Tray Cover.
Applied Biosystems™ TaqMan™ Universal PCR Master Mix, no AmpErase™ UNG
TaqMan™ Universal PCR Master Mix, No AmpErase™ UNG is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications.
Shipping Condition | Wet Ice |
---|---|
Polymerase | AmpliTaq Gold DNA Polymerase |
GC-Rich PCR Performance | High |
Product Type | Universal PCR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
Sample Type | DNA (Genomic), cDNA |
Reaction Speed | Standard |
For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
PCR Method | qPCR |
Product Line | TaqMan™ |
Detection Method | Primer-probe |
Applied Biosystems™ Sanger Sequencing Kit
Sanger Sequencing Kit includes all reagents needed for sample preparation for sanger sequencing
Applied Biosystems™ MicroAmp™ Fast Optical 48-Well Reaction Plate
Optimized to provide unmatched temperature accuracy and uniformity for fast, efficient PCR amplification
Applied Biosystems™ POP-7™ Polymer, for 3500/SeqStudio™ Flex
POP-4, POP-6, and POP-7 are conveniently offered in easy to use pouch packages. The POP-7 separation matrix is optimized for short- to long-read sequencing and fragment analysis.
For Use With (Application) | Long-Read Sequencing, Short Read Sequencing, Fragment Analysis (Denaturing) |
---|---|
Product Line | POP-7™ |