UV-Vis Spectrophotometers
UV-Vis Spectrophotometers
- (1)
- (3)
- (4)
- (11)
- (1)
- (2)
- (9)
- (8)
- (1)
- (2)
- (1)
- (1)
- (2)
- (2)
- (9)
- (1)
- (4)
- (1)
- (1)
- (2)
- (3)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (6)
Filtered Search Results
Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis Spectrophotometers
Optimized for your water analysis needs AquaMate 7100 Vis and AquaMate 8100 UV-Vis Spectrophotometers provide fast and reliable results
Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
---|---|
Connections | Single USB-A Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Height (Metric) | 19.5 cm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
Warranty | 1 Year |
Length (Metric) | 35.5 cm |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Wavelength Repeatability | < ±0.2 nm |
For Use With (Application) | Water and Waste Water Analysis |
Width (Metric) | 38.5 cm |
Detector Type | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Wavelength Accuracy | ±0.5 nm |
Depth (Metric) | 35.5 cm |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100 mm cells Available accessory for test tubes up to 25 mm diameter and 150 mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Keypad | Glove- friendly touchscreen |
Certifications/Compliance | CE / TUV |
Optical Design | Double Beam |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Interface | Glove friendly touch-screen |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Display | 7 in. High Definition Color Touchscreen, Fixed, 800 x 1280 pixels |
Biochrom Ultrospec™ 30 Cell Density Meter
Ultrospec™ 30 Cell Density Meter for measuring density of bacteria and yeast cells in suspension.
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.
Spectral Bandwidth | 2 nm |
---|---|
Optical Design | Double Beam |
Thermo Scientific™ BioMate™ 160 UV-Vis Spectrophotometer
Perform automated measurements of nucleic acids, proteins and cell cultures with the Thermo Scientific BioMate 160 UV-Vis spectrophotometer.
Spectral Bandwidth | 2 nm |
---|
Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. diagonal, 32-bit Color Display, 800 x 480 pixels |
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Thermo Scientific™ SPECTRONIC 200™ Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the new standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Connections | USB-B for connection to a remote computer USB-A for connection to a printer or USB memory device |
---|---|
Width (English) | 15.3 in. |
Printer Included | External printer support: Epson TM-T88V |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese, Korean, Thai |
Photometric Readout | ABS, %T, Concentration (standard or custom units) |
Light Source | Tungsten Halogen |
Width (Metric) | 39 cm |
Includes | Two Cuvet Racks; Ten 1cm plastic cuvets |
Detector Type | 2048-element CCD |
Compartments | Removable, washable sample compartment |
Stray Light | <0.2%T (with SPECTRONIC standard SRM 400 filter) |
Optical Design | Single Beam |
Photometric Repeatability | ±0.03 A at 0.3 A |
Weight (Metric) | 5.2 kg |
Height (English) | 3.6 in. |
Height (Metric) | 16 cm |
Electrical Requirements | Selected automatically, 100/240 V, 50/60Hz |
Depth (English) | 11.8 in. |
Photometric Range | -0.3 to 2.5Å |
Wavelength Repeatability | ±1nm |
Data Interval for Scanning | 1 nm on-board, 0.5 nm under computer control |
Spectral Bandwidth | <4 nm |
Photometric Display | -0.3A - 2.5A; 0 - 125%T |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Depth (Metric) | 30 cm |
Keypad | Sealed tactile rubber |
Container Type | Single cell holder for square cuvettes and for test tubes |
Weight (English) | 9.7 lb. |
Interface | USB-B; USB-A |
Wavelength Range | 340 to 1000 nm |
Display | Color graphical TFT LCD, 3.5 in. diagonal |
Thermo Scientific™ SPECTRONIC™ 200 Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Biochrom WPA S1200+ Visible Spectrophotometer
Biochrom's WPA S1200+ visible spectrophotometer has been designed to meet the routine spectroscopy needs of customers requiring a small, lightweight instruments that is easy to use.
Biochrom Novaspec III+ Spectrophotometer
Designed for a wide range of applications, this visible spectrophotometer is portable, reliable and easy to use. The Biochrom Novaspec III+ Spectrophotometer features a small footprint and rugged lightweight construction, ideal for laboratories where space is at a minimum.
Biochrom WPA S800+ Visible Spectrophotometer
The Biochrom WPA S800+ Visible Spectrophotometer is designed to make life easier for technical staff and to be low maintenance under demanding conditions.
Thermo Scientific™ GENESYS™ 150 UV-Vis Spectrophotometer PROMO
The GENESYS 150 UV-Vis Spectrophotometer provides automation for high-throughput options and room-light resistance, allowing lid-open operation for improved speed and convenience.
Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
---|---|
Connections | Single USB-A Duplex USB-A Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Electrical Requirements | External AC/DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Printer Included | Snap-on printer available |
Noise | (RMS at 500 nm 60 consecutive measurements); ≤0.00020 A at 0 A at 260 and 500 nm; ≤0.00030 A at 1 A at 260 and 500 nm; ≤0.00040 A at 2 A at 260 and 500 nm |
Photometric Range | –2 A to +3.5 A |
Wavelength Repeatability | < ±0.2 nm |
Spectral Bandwidth | 2 nm |
Baseline Flatness | ±0.002 A |
Detector Type | Dual Silicon Photodiodes |
Photometric Display | –3 A to +5 A |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Wavelength Accuracy | ±0.5 nm |
Lamp Life | > 5 years typical, 3 years guaranteed |
Compartments | Accommodates (optional): 8-position cell changer, 4-position cell changer (long path cells), Peltier thermostatted cell holder (20 to 60 °C), Sipper accessory, Fiber optic probe coupler |
Keypad | Touchscreen |
Stray Light | <1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
Drift | (At 500 nm after 1 hour warmup) < 0.0005 A/hr. |
Optical Design | Double Beam |
Photometric Repeatability | ±0.001 A at 1 A measured at 1.0 A at 546 nm |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Biochrom Novaspec Pro Spectrophotometer
Designed for general biotech laboratory use, this spectrophotometer is lightweight and easy to use. The Biochrom Novaspec Pro Spectrophotometer features a small footprint and rugged lightweight construction, ideal for laboratories where space is at a minimum.
Jenway™ 7200 Visible Scanning Spectrophotometer
Leverage diode array technology for fast results with this visible scanning spectrophotometer. Jenway™ 7200 Visible Scanning Spectrophotometer is ideal for a variety of applications in education and routine testing in clinical, veterinary, pharmaceutical and QC laboratories.
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer, UK Power Cable
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.